FrequencyContinuousSettings

Advanced continuous frequency properties.

Example

application = cf.Application.getInstance()
project = application:NewProject()

    -- Initialise the frequency to a continuous band

frequency = project.Contents.SolutionConfigurations.GlobalFrequency
properties = frequency:GetProperties()
properties.Start = 100e6
properties.End = 200e6
properties.RangeType = cf.Enums.FrequencyRangeTypeEnum.Continuous
frequency:SetProperties(properties)

    -- Set the maximum number of samples
    -- As the properties need to be modified in one step,
    -- a properties table is used

properties = frequency:GetProperties()
properties.Advanced.Continuous.MaxSamplesEnabled = true
properties.Advanced.Continuous.MaxSamples = 10
frequency:SetProperties(properties)

Inheritance

The FrequencyContinuousSettings object is derived from the CompositeValue object.

Usage locations

The FrequencyContinuousSettings object can be accessed from the following locations:

Property List

ConvergenceAccuracy
Control the speed and accuracy of convergence. (Read/Write FrequencyConvergenceAccuracyTypeEnum)
MaxSamples
A limit to the maximum number of solutions. Only valid if MaxSamplesEnabled is true. (Read/Write ParametricExpression)
MaxSamplesEnabled
Apply a limit to the maximum number of solutions when using continuous frequency. (Read/Write boolean)
MinIncrement
A limit to how far the Feko Solver refines the frequency (Hz). Only valid if MinIncrementEnabled is true. (Read/Write ParametricExpression)
MinIncrementEnabled
Apply a limit to how far the Feko Solver refines the frequency when using continuous frequency. (Read/Write boolean)
Quantities
Quantities to include for adaptive frequency sampling. (Read/Write FrequencyContinuousQuantities)

Property Details

ConvergenceAccuracy
Control the speed and accuracy of convergence.
Type
FrequencyConvergenceAccuracyTypeEnum
Access
Read/Write
MaxSamples
A limit to the maximum number of solutions. Only valid if MaxSamplesEnabled is true.
Type
ParametricExpression
Access
Read/Write
MaxSamplesEnabled
Apply a limit to the maximum number of solutions when using continuous frequency.
Type
boolean
Access
Read/Write
MinIncrement
A limit to how far the Feko Solver refines the frequency (Hz). Only valid if MinIncrementEnabled is true.
Type
ParametricExpression
Access
Read/Write
MinIncrementEnabled
Apply a limit to how far the Feko Solver refines the frequency when using continuous frequency.
Type
boolean
Access
Read/Write
Quantities
Quantities to include for adaptive frequency sampling.
Type
FrequencyContinuousQuantities
Access
Read/Write