ValveEdgeTableAx

    ValveEdgeTableAx

Library

Components/Valves/Base

Description

The component ValveEdgeTableAx is a model of a flow resistance that behaves like an orifice.

The parameterization of the ValveEdgeTableAx is done by providing the Flow coefficient alphaD and a look-up table of the Cross-sectional area as a function of the input signal. Further information regarding the formatting of the look-up table can be found in the documentation of the component ResistorTableAx. Unlike the Resistor component, the look-up table for valveEdgeTableAx is declared for the input range from -1 to 1.

The flow rate is calculated based on Flow coefficient alphaD, Cross-sectional area, density of the fluid and pressure difference between the two edges of the valve, according to the formula given below:

By variation in input signal, the cross sectional area of the valve edge is changed which in turn changes the flow through the valve edge.

Parameters

ValveEdgeTableAx_0

NameLabelDescriptionData TypeValid Values

mo_forwardFluidProperties

forwardFluidProperties

Forward fluid properties between ports

Scalar

true
false

ValveEdgeTableAx_1

NameLabelDescriptionData TypeValid Values

mo_tableFromFile

tableFromFile

Table is provided by file

Scalar

true
false

mo_fileName

fileName

File where look-up table is stored

String

mo_tableName

tableName

Table name on file

String

mo_manualTable

manualTable

Manually provided look-up table

Matrix

mo_alphaD

alphaD

Flow coefficient alphaD

Scalar

mo_inputMin

inputMin

Minimum value of the input for look-up table

Scalar

ValveEdgeTableAx_2

NameLabelDescriptionData TypeValid Values

mo_Input

Input

Input

Structure

mo_Input/fixed

fixed

Cell of scalars

true
false

mo_Input/start

start

Cell of scalars

mo_Offset

Offset

Offset

Structure

mo_Offset/fixed

fixed

Cell of scalars

true
false

mo_Offset/start

start

Cell of scalars

mo_InputMax

InputMax

InputMax

Structure

mo_InputMax/fixed

fixed

Cell of scalars

true
false

mo_InputMax/start

start

Cell of scalars

mo_dp

dp

dp

Structure

mo_dp/fixed

fixed

Cell of scalars

true
false

mo_dp/start

start

Cell of scalars

mo_volumeFlowA

volumeFlowA

volumeFlowA

Structure

mo_volumeFlowA/fixed

fixed

Cell of scalars

true
false

mo_volumeFlowA/start

start

Cell of scalars

mo_volumeFlowB

volumeFlowB

volumeFlowB

Structure

mo_volumeFlowB/fixed

fixed

Cell of scalars

true
false

mo_volumeFlowB/start

start

Cell of scalars

Ports

NameTypeDescriptionIO TypeNumber

Input

implicit

input

1

Offset

implicit

input

2

InputMax

implicit

input

3

portA

implicit

input

4

portB

implicit

input

5