LogicToX01
Conversion to X01
Library
Electrical/Digital/Converters
Description
Conversion of a nine valued digital input into a X01 digital output without any delay according to IEEE 1164 To_X01 function.
Conversion Table:
input output 'U' (coded by 1) 'X' (coded by 2) 'X' (coded by 2) 'X' (coded by 2) '0' (coded by 3) '0' (coded by 3) '1' (coded by 4) '1' (coded by 4) 'Z' (coded by 5) 'X' (coded by 2) 'W' (coded by 6) 'X' (coded by 2) 'L' (coded by 7) '0' (coded by 3) 'H' (coded by 8) '1' (coded by 4) '-' (coded by 9) 'X' (coded by 2)
If the signal width is greater than 1 this conversion is done for each signal.
Parameters
Name | Label | Description | Data Type | Valid Values |
---|---|---|---|---|
mo_n | n | signal width | Scalar |
Name | Label | Description | Data Type | Valid Values |
---|---|---|---|---|
mo_x | x | x | Structure | |
mo_x/fixed | fixed | Cell of vectors | true | |
mo_x/start | start | Cell of vectors | ||
mo_y | y | y | Structure | |
mo_y/fixed | fixed | Cell of vectors | true | |
mo_y/start | start | Cell of vectors |
Ports
Name | Type | Description | IO Type | Number |
---|---|---|---|---|
x | implicit | input | 1 | |
y | implicit | output | 1 |