IdealClosingSwitch

Multiphase ideal closer

    IdealClosingSwitch

Library

Electrical/QuasiStationary/MultiPhase/Ideal

Description

Contains m ideal closing switches (Modelica.Electrical.QuasiStationary.SinglePhase.Ideal.IdealClosingSwitch).

Use with care: This switch is only intended to be used for structural changes, not fast switching sequences, due to the quasistationary formulation.

Parameters

IdealClosingSwitch_0

NameLabelDescriptionData TypeValid Values

mo_m

m

Number of phases

Scalar

mo_Ron

Ron

Closed switch resistance

Vector

mo_Goff

Goff

Opened switch conductance

Vector

mo_mh

mh

Number of heatPorts=number of phases

Scalar

mo_useHeatPort

useHeatPort

=true, if all heat ports are enabled

Number

0
1

mo_T

T

Fixed device temperatures if useHeatPort = false

Vector

IdealClosingSwitch_1

NameLabelDescriptionData TypeValid Values

mo_abs_v

abs_v

abs_v

Structure

mo_abs_v/fixed

fixed

Cell of vectors

true
false

mo_abs_v/start

start

Cell of vectors

mo_arg_v

arg_v

arg_v

Structure

mo_arg_v/fixed

fixed

Cell of vectors

true
false

mo_arg_v/start

start

Cell of vectors

mo_abs_i

abs_i

abs_i

Structure

mo_abs_i/fixed

fixed

Cell of vectors

true
false

mo_abs_i/start

start

Cell of vectors

mo_arg_i

arg_i

arg_i

Structure

mo_arg_i/fixed

fixed

Cell of vectors

true
false

mo_arg_i/start

start

Cell of vectors

mo_P

P

P

Structure

mo_P/fixed

fixed

Cell of vectors

true
false

mo_P/start

start

Cell of vectors

mo_P_total

P_total

P_total

Structure

mo_P_total/fixed

fixed

Cell of scalars

true
false

mo_P_total/start

start

Cell of scalars

mo_Q

Q

Q

Structure

mo_Q/fixed

fixed

Cell of vectors

true
false

mo_Q/start

start

Cell of vectors

mo_Q_total

Q_total

Q_total

Structure

mo_Q_total/fixed

fixed

Cell of scalars

true
false

mo_Q_total/start

start

Cell of scalars

mo_S

S

S

Structure

mo_S/fixed

fixed

Cell of vectors

true
false

mo_S/start

start

Cell of vectors

mo_S_total

S_total

S_total

Structure

mo_S_total/fixed

fixed

Cell of scalars

true
false

mo_S_total/start

start

Cell of scalars

mo_pf

pf

pf

Structure

mo_pf/fixed

fixed

Cell of vectors

true
false

mo_pf/start

start

Cell of vectors

mo_omega

omega

omega

Structure

mo_omega/fixed

fixed

Cell of scalars

true
false

mo_omega/start

start

Cell of scalars

mo_control

control

control

Structure

mo_control/fixed

fixed

Cell of vectors

true
false

mo_control/start

start

Cell of vectors

Ports

NameTypeDescriptionIO TypeNumber

plug_p

implicit

Positive quasi-static polyphase plug

input

1

plug_n

implicit

Negative quasi-static polyphase plug

output

1

control

implicit

true => p--n connected, false => switch open

input

2

Port 4

implicit

Conditional heat ports

input

mo_useHeatPort