CuboidOrthogonalFlux

Cuboid with flux orthogonal to direction of motion; constant permeability

    CuboidOrthogonalFlux

Library

Magnetic/FluxTubes/Shapes/Force

Description

Please refer to the enclosing sub-package Force for a description of all elements of this package and to [Ro41] for derivation and/or coefficients of the equation for permeance G_m.

Parameters

CuboidOrthogonalFlux_0

NameLabelDescriptionData TypeValid Values

mo_useSupport

useSupport

= true, if support flange enabled, otherwise implicitly grounded

Number

0
1

mo_mu_r

mu_r

Relative magnetic permeability

Scalar

mo_dlBydx

dlBydx

Derivative of flux tube's varying dimension with respect to armature position; set to +1 or -1

Scalar

mo_l

l

Length in direction of motion (orthogonal to flux)

Scalar

mo_a

a

Width of rectangular cross-section

Scalar

mo_b

b

Height of rectangular cross-section (in flux direction)

Scalar

CuboidOrthogonalFlux_1

NameLabelDescriptionData TypeValid Values

mo_V_m

V_m

V_m

Structure

mo_V_m/fixed

fixed

Cell of scalars

true
false

mo_V_m/start

start

Cell of scalars

mo_Phi

Phi

Phi

Structure

mo_Phi/fixed

fixed

Cell of scalars

true
false

mo_Phi/start

start

Cell of scalars

mo_F_m

F_m

F_m

Structure

mo_F_m/fixed

fixed

Cell of scalars

true
false

mo_F_m/start

start

Cell of scalars

mo_s

s

s

Structure

mo_s/fixed

fixed

Cell of scalars

true
false

mo_s/start

start

Cell of scalars

mo_R_m

R_m

R_m

Structure

mo_R_m/fixed

fixed

Cell of scalars

true
false

mo_R_m/start

start

Cell of scalars

mo_G_m

G_m

G_m

Structure

mo_G_m/fixed

fixed

Cell of scalars

true
false

mo_G_m/start

start

Cell of scalars

mo_dGmBydx

dGmBydx

dGmBydx

Structure

mo_dGmBydx/fixed

fixed

Cell of scalars

true
false

mo_dGmBydx/start

start

Cell of scalars

mo_B

B

B

Structure

mo_B/fixed

fixed

Cell of scalars

true
false

mo_B/start

start

Cell of scalars

Ports

NameTypeDescriptionIO TypeNumber

port_p

implicit

Positive magnetic port

input

1

port_n

implicit

Negative magnetic port

output

1

flange

implicit

Generated reluctance force at armature position

output

2

Port 4

implicit

Support/housing of component

input

mo_useSupport