Convection
Lumped thermal element for heat convection (Q_flow = Gc*dT)
Library
Thermal/HeatTransfer/Components
Description
This is a model of linear heat convection, e.g., the heat transfer between a plate and the surrounding air; see also: ConvectiveResistor. It may be used for complicated solid geometries and fluid flow over the solid by determining the convective thermal conductance Gc by measurements. The basic constitutive equation for convection is
Q_flow = Gc*(solid.T - fluid.T); Q_flow: Heat flow rate from connector 'solid' (e.g., a plate) to connector 'fluid' (e.g., the surrounding air)
Gc = G.signal[1] is an input signal to the component, since Gc is nearly never constant in practice. For example, Gc may be a function of the speed of a cooling fan. For simple situations, Gc may be calculated according to
Gc = A*h A: Convection area (e.g., perimeter*length of a box) h: Heat transfer coefficient
where the heat transfer coefficient h is calculated from properties of the fluid flowing over the solid. Examples:
Machines cooled by air (empirical, very rough approximation according to R. Fischer: Elektrische Maschinen, 10th edition, Hanser-Verlag 1999, p. 378):
h = 7.8*v^0.78 [W/(m2.K)] (forced convection) = 12 [W/(m2.K)] (free convection) where v: Air velocity in [m/s]
Laminar flow with constant velocity of a fluid along a flat plate where the heat flow rate from the plate to the fluid (= solid.Q_flow) is kept constant (according to J.P.Holman: Heat Transfer, 8th edition, McGraw-Hill, 1997, p.270):
h = Nu*k/x; Nu = 0.453*Re^(1/2)*Pr^(1/3); where h : Heat transfer coefficient Nu : = h*x/k (Nusselt number) Re : = v*x*rho/mue (Reynolds number) Pr : = cp*mue/k (Prandtl number) v : Absolute velocity of fluid x : distance from leading edge of flat plate rho: density of fluid (material constant mue: dynamic viscosity of fluid (material constant) cp : specific heat capacity of fluid (material constant) k : thermal conductivity of fluid (material constant) and the equation for h holds, provided Re < 5e5 and 0.6 < Pr < 50
Parameters
Name | Label | Description | Data Type | Valid Values |
---|---|---|---|---|
mo_Q_flow | Q_flow | Q_flow | Structure | |
mo_Q_flow/fixed | fixed | Cell of scalars | true | |
mo_Q_flow/start | start | Cell of scalars | ||
mo_dT | dT | dT | Structure | |
mo_dT/fixed | fixed | Cell of scalars | true | |
mo_dT/start | start | Cell of scalars | ||
mo_Gc | Gc | Gc | Structure | |
mo_Gc/fixed | fixed | Cell of scalars | true | |
mo_Gc/start | start | Cell of scalars |
Ports
Name | Type | Description | IO Type | Number |
---|---|---|---|---|
Gc | implicit | Signal representing the convective thermal conductance in [W/K] | input | 1 |
solid | implicit | input | 2 | |
fluid | implicit | output | 1 |