HeatFlowSensor

Heat flow rate sensor

    HeatFlowSensor

Library

Thermal/HeatTransfer/Sensors

Description

This model is capable of monitoring the heat flow rate flowing through this component. The sensed value of heat flow rate is the amount that passes through this sensor while keeping the temperature drop across the sensor zero. This is an ideal model so it does not absorb any energy and it has no direct effect on the thermal response of a system it is included in. The output signal is positive, if the heat flows from port_a to port_b.

Parameters

HeatFlowSensor_0

NameLabelDescriptionData TypeValid Values

mo_Q_flow

Q_flow

Q_flow

Structure

mo_Q_flow/fixed

fixed

Cell of scalars

true
false

mo_Q_flow/start

start

Cell of scalars

Ports

NameTypeDescriptionIO TypeNumber

Q_flow

implicit

Heat flow from port_a to port_b as output signal

output

1

port_a

implicit

input

1

port_b

implicit

output

2