Description

The component Throttle is a model of a fluid resistance with to a large extent linear shaped dependence of the VolumeFlow on the pressure difference pA-pB connected to the component.

It is parameterized by the geometric parameters Diameter and Length. The kinetic viscosity of the fluid and its density are considered in their temperature dependency.

The Throttle is suitable for modeling a bore, if the ratio of its length l to its diameter d is comparatively large (approx. l/d > 10). It does not take any inductance into consideration. If desired, a PipeWithoutCapacity or a Pipe is the correct component instead.

Parameters

Throttle_0

NameLabelDescriptionData TypeValid Values

mo_diameter

diameter

Diameter

Scalar

mo_length

length

Length

Scalar

Throttle_1

NameLabelDescriptionData TypeValid Values

mo_forwardFluidProperties

forwardFluidProperties

Forward fluid properties between ports

Scalar

true
false

Throttle_2

NameLabelDescriptionData TypeValid Values

mo_volumeFlowA

volumeFlowA

volumeFlowA

Structure

mo_volumeFlowA/fixed

fixed

Cell of scalars

true
false

mo_volumeFlowA/start

start

Cell of scalars

mo_volumeFlowB

volumeFlowB

volumeFlowB

Structure

mo_volumeFlowB/fixed

fixed

Cell of scalars

true
false

mo_volumeFlowB/start

start

Cell of scalars

Ports

NameTypeDescriptionIO TypeNumber

fluidPortA

implicit

Hydraulic port A

input

1

fluidPortB

implicit

Hydraulic port B

input

2