PropValve22PT2TableAx

    PropValve22PT2TableAx

Library

Components/Valves/DirectionalValves

Description

The component PropValve22PT2TableAx is a model of a 2-way proportional valve where the stroke follows the input signal with a 2nd order delay.

The parameterization of the meetering edge is done by providing the Flow coefficient alphaD and a look-up table of the Cross-sectional area as a function of the input signal. Further information regarding the formatting of the look-up table can be found in the documentation of the component ResistorTableAx.

For a positive stroke, the cross-sectional area of the valve's meetering edge is given as a function of the input signal through a look-up table starting from 0 to maximum area (the cross-sectional area of the valve when it is completely open). The cross-sectional area must be given in m^2. The flow is then calculated based on Flow coefficient alphaD, Cross-sectional area, density of the fluid and pressure difference between the two edges of the valve, according to the formula given below:

The valve stroke can be shifted by Relative overlap general. In accordance with common valve parameters a negative overlap will open the valve edge.

Parameters

PropValve22PT2TableAx_0

NameLabelDescriptionData TypeValid Values

mo_inputMax

inputMax

Input value for 100 % open

Scalar

mo_angFreq

angFreq

Angular frequency

Scalar

mo_damping

damping

Damping

Scalar

mo_vMax

vMax

max. Velocity

Scalar

mo_vMin

vMin

min. Velocity

Scalar

mo_enableStrokeOut

enableStrokeOut

Enable Stroke Output

Number

0
1

mo_deadVolume

deadVolume

Dead volume at ports

Scalar

mo_inputMaxPartial

inputMaxPartial

Scalar

mo_initType

initType

Type of initialization (1: no init, 2: steady state, 3/4: initial output)

Structure

mo_initType/choice1

No initialization (start values are used as guess values with fixed=false)

Number

0
1

mo_initType/choice2

Steady state initialization (derivatives of states are zero)

Number

0
1

mo_initType/choice3

Initialization with initial states

Number

0
1

mo_initType/choice4

Initialization with initial outputs (and steady state of the states if possible)

Number

0
1

PropValve22PT2TableAx_1

NameLabelDescriptionData TypeValid Values

mo_Overlap

Overlap

Valve edge relative overlap

Scalar

mo_alphaD

alphaD

Flow coefficient alphaD

Scalar

mo_tableFromFile

tableFromFile

Table is provided by file

Scalar

true
false

mo_fileName

fileName

File where look-up table is stored

String

mo_tableName

tableName

Table name on file

String

mo_manualTable

manualTable

Manually provided look-up table

Matrix

mo_QFactorPA

QFactorPA

Factor for edge specific flow adjustment

Scalar

PropValve22PT2TableAx_2

NameLabelDescriptionData TypeValid Values

mo_valveStrokeOut

valveStrokeOut

valveStrokeOut

Structure

mo_valveStrokeOut/fixed

fixed

Cell of scalars

true
false

mo_valveStrokeOut/start

start

Cell of scalars

mo_pP

pP

pP

Structure

mo_pP/fixed

fixed

Cell of scalars

true
false

mo_pP/start

start

Cell of scalars

mo_pA

pA

pA

Structure

mo_pA/fixed

fixed

Cell of scalars

true
false

mo_pA/start

start

Cell of scalars

mo_Input

Input

Input

Structure

mo_Input/fixed

fixed

Cell of scalars

true
false

mo_Input/start

start

Cell of scalars

mo_Stroke

Stroke

Stroke

Structure

mo_Stroke/fixed

fixed

Cell of scalars

true
false

mo_Stroke/start

start

Cell of scalars

mo_Velocity

Velocity

Velocity

Structure

mo_Velocity/fixed

fixed

Cell of scalars

true
false

mo_Velocity/start

start

Cell of scalars

Ports

NameTypeDescriptionIO TypeNumber

portA

implicit

Hydraulic port A

input

1

portP

implicit

Hydraulic port P

input

2

Input

implicit

Set value of valve position

input

3

Port 4

implicit

Valve Stroke

output

mo_enableStrokeOut