OpenTank

    OpenTank

Library

Components/Volumes

Description

The OpenTank component is the model of an open tank with unlimited volume in the sense of a line termination. The pressure at fluidPort can either be set to environment.pAmbient pressure or a different pressure.

Parameters

OpenTank_0

NameLabelDescriptionData TypeValid Values

mo_useEnvironmentPressure

useEnvironmentPressure

Pressure at the fluid port equals environment.pAmbient

Scalar

true
false

mo_pressure

pressure

Pressure at the fluid port if useAmbientPressure = false

Scalar

Ports

NameTypeDescriptionIO TypeNumber

fluidPort

implicit

Hydraulic port

input

1