PrescribedTemperature

Variable temperature boundary condition in Kelvin

    PrescribedTemperature

Library

Thermal/HeatTransfer/Sources

Description

This model represents a variable temperature boundary condition. The temperature in [K] is given as input signal T to the model. The effect is that an instance of this model acts as an infinite reservoir able to absorb or generate as much energy as required to keep the temperature at the specified value.

Parameters

PrescribedTemperature_0

NameLabelDescriptionData TypeValid Values

mo_T

T

T

Structure

mo_T/fixed

fixed

Cell of scalars

true
false

mo_T/start

start

Cell of scalars

Ports

NameTypeDescriptionIO TypeNumber

port

implicit

output

1

T

implicit

input

1