Click BC under Edit Attributes to access the BC submenu. The BC macros help you easily create injection and cooling inlet locations.
The Set Injection Locations macro opens the Create Injection Location BC dialog. Select whether to use an existing load collector or to create a new load collector for the injection location boundary condition. If you select New collector, type a name for the load collector in the adjacent field. If you select Existing collector, select a collector from the adjacent drop-down list. Click Create. Then select a node from the graphics display that corresponds to the injection location. Click proceed. An injection boundary condition is created at the selected node.
The Set Coolant Inlets macro opens the Create Coolant Inlet BC dialog. Select whether to use an existing load collector or to create a new load collector for the coolant inlet boundary condition. If you select New collector, type a name for the load collector in the adjacent field. If you select Existing collector, select a collector from the adjacent drop-down list. Click Create. Then select a node from the graphics display that corresponds to the coolant inlet location. Click proceed. A coolant inlet boundary condition is created at the selected node.