The HyperForm RADIOSS One Step solvers and RADIOSS Incremental solvers are unit neutral. However, it is important to maintain unit consistency.
The following units are recommended for RADIOSS One Step analysis:
Measure |
Recommended Unit |
Length |
mm |
Stress |
MPa |
Blankholder force on elements |
metric ton: 1 ton = 9810N |
Blankholder force on edge |
N/mm |
Drawbead force |
N/mm |
The following units are recommended for RADIOSS Incremental analysis:
Measure |
Recommended Unit |
Length |
mm |
Stress |
MPa |
Blankholder force |
N |
Drawbead force |
N/mm |
Density |
Mg/mm3 |
Time |
s |
Velocity |
mm/s |