Package HydraulicsByFluidon.​Components.​Base
Icon for standard packages

Information

Standard package icon.

Extends from Modelica.​Icons.​Package (Icon for standard packages).

Package Contents

NameDescription
Capacity 
ExtendedCapacity 
HydTwoPortVertical 
HydTwoPortVerticalExt 
PartialCylinder 
PartialHydroMotor 
PartialReliefResistor 
PartialReliefResistorBase 
PartialResistorBase 
PartialResistorVariable 
SimpleCylinder 
SimpleDisplacementMachineTwoDir 
SimplePlunger 

Model HydraulicsByFluidon.​Components.​Base.​Capacity

Connectors

TypeNameDescription
FluidPortfluidPortHydraulic port

Model HydraulicsByFluidon.​Components.​Base.​ExtendedCapacity

Parameters

TypeNameDefaultDescription
Volumecapacity  
BulkModulusbulkModulus2.1e+11 

Connectors

TypeNameDescription
FluidPortfluidPortHydraulic port

Partial Model HydraulicsByFluidon.​Components.​Base.​HydTwoPortVertical

Parameters

TypeNameDefaultDescription
BooleanforwardFluidPropertiestrueForward fluid properties between ports

Connectors

TypeNameDescription
FluidPortfluidPortAHydraulic port A
FluidPortfluidPortBHydraulic port B

Partial Model HydraulicsByFluidon.​Components.​Base.​HydTwoPortVerticalExt

Extends from HydraulicsByFluidon.​Components.​Base.​HydTwoPortVertical.

Parameters

TypeNameDefaultDescription
BooleanforwardFluidPropertiestrueForward fluid properties between ports

Connectors

TypeNameDescription
FluidPortfluidPortAHydraulic port A
FluidPortfluidPortBHydraulic port B

Partial Model HydraulicsByFluidon.​Components.​Base.​PartialResistorBase

Information

The component PartialResistorBase is the basic model of a flow resistance.

Extends from HydraulicsByFluidon.​Components.​Base.​HydTwoPortVertical.

Parameters

TypeNameDefaultDescription
BooleanforwardFluidPropertiestrueForward fluid properties between ports

Connectors

TypeNameDescription
FluidPortfluidPortAHydraulic port A
FluidPortfluidPortBHydraulic port B

Partial Model HydraulicsByFluidon.​Components.​Base.​PartialResistorVariable

Information

The component PartialIdealResistor is the basic model of a flow resistance that behaves either like an orifice or a throttle, depending on the parameter setting.

Flow is adjusted via the Input signal with nominal flow (as given by nominal flow/ nominal pressure difference) corresponding to an input value of 1.

Extends from HydraulicsByFluidon.​Components.​Base.​PartialResistorBase.

Parameters

TypeNameDefaultDescription
BooleanforwardFluidPropertiestrueForward fluid properties between ports
TResistorTypesresistorTypeHydraulicsByFluidon.​Types.​TResistorTypes.​OrificeType of the resistor
VolumeFlowRateNominalVolumeFlow5e-4Nominal volume flow
PressureNominalPressureDifference500000Nominal pressure difference
DensityReferenceDensity860Reference density

Connectors

TypeNameDescription
FluidPortfluidPortAHydraulic port A
FluidPortfluidPortBHydraulic port B

Model HydraulicsByFluidon.​Components.​Base.​SimpleCylinder

Information

Simple model of a cylinder with Stribeck friction.

Extends from HydraulicsByFluidon.​Components.​Base.​PartialCylinder.

Parameters

TypeNameDefaultDescription
LengthpistonDiameter0.1Piston diameter
LengthrodDiameterA0Rod diameter @ port A
LengthrodDiameterB0.05Rod diameter @ port B
LengthcylinderLength0.2Cylinder length
LengthrodLength1Rod length @ port B
Angleangle0Inclination angle
VolumedeadVolume1e-4Dead volume
MassmassPiston50Piston mass
MassmassCylinder40Cylinder mass
RealfProp10000Velocity dependent friction
ForcefCoulomb250Constant friction: Coulomb force
ForcefBreakaway500Breakaway force
VelocityvM0.005Velocity parameter for Stribeck friction
BooleanrelFricfalseif selected, relative friction is calculated based on relFricFactor
RealrelFricFactor0 
VelocityvSmall0.001 
BooleanforwardFluidPropertiesfalseForward fluid properties between ports

Connectors

TypeNameDescription
Flange_aflange_c 
Flange_bflange_p 
FluidPortfluidPortAHydraulic port A
output RealOutputstrokeOutRelative position of piston
FluidPortfluidPortBHydraulic port B

Model HydraulicsByFluidon.​Components.​Base.​SimplePlunger

Information

Simple model of a plunger cylinder with Stribeck friction, gravitational forces and consideration of dynamic fluid mass.

Extends from HydraulicsByFluidon.​Components.​Base.​PartialCylinder.

Parameters

TypeNameDefaultDescription
LengthpistonDiameter0.1Piston diameter
LengthrodDiameterA0Rod diameter @ port A
LengthrodDiameterB0.05Rod diameter @ port B
LengthcylinderLength0.2Cylinder length
LengthrodLength1Rod length @ port B
Angleangle0Inclination angle
VolumedeadVolume1e-4Dead volume
MassmassPiston50Piston mass
MassmassCylinder40Cylinder mass
RealfProp10000Velocity dependent friction
ForcefCoulomb250Constant friction: Coulomb force
ForcefBreakaway500Breakaway force
VelocityvM0.005Velocity parameter for Stribeck friction
BooleanrelFricfalseif selected, relative friction is calculated based on relFricFactor
RealrelFricFactor0 
VelocityvSmall0.001 

Connectors

TypeNameDescription
Flange_aflange_c 
Flange_bflange_p 
FluidPortfluidPortAHydraulic port A
output RealOutputstrokeOutRelative position of piston

Partial Model HydraulicsByFluidon.​Components.​Base.​PartialCylinder

Information

Partial model of a cylinder with Stribeck friction, gravitational forces and consideration of dynamic fluid mass.

Parameters

TypeNameDefaultDescription
LengthpistonDiameter0.1Piston diameter
LengthrodDiameterA0Rod diameter @ port A
LengthrodDiameterB0.05Rod diameter @ port B
LengthcylinderLength0.2Cylinder length
LengthrodLength1Rod length @ port B
Angleangle0Inclination angle
VolumedeadVolume1e-4Dead volume
MassmassPiston50Piston mass
MassmassCylinder40Cylinder mass
RealfProp10000Velocity dependent friction
ForcefCoulomb250Constant friction: Coulomb force
ForcefBreakaway500Breakaway force
VelocityvM0.005Velocity parameter for Stribeck friction
BooleanrelFricfalseif selected, relative friction is calculated based on relFricFactor
RealrelFricFactor0 
VelocityvSmall0.001 

Connectors

TypeNameDescription
Flange_aflange_c 
Flange_bflange_p 
FluidPortfluidPortAHydraulic port A
output RealOutputstrokeOutRelative position of piston

Partial Model HydraulicsByFluidon.​Components.​Base.​PartialHydroMotor
Partial Pump

Extends from HydraulicsByFluidon.​Components.​Pumps.​Interfaces.​PartialPump (Partial Pump).

Parameters

TypeNameDefaultDescription
VolumedispVolume5e-5Displacement volume
InertiaJrot0.05Rotational moment of inertia
VolumedeadVolume1e-6Dead volume at ports
EfficiencyetaVol0.94Volumetric efficiency @ nRef, dpRef
DensityleakageReferenceDensity860Reference density for volumetric efficiency
DimensionlessRatioratioLeakageExtern0Ratio external Leakage / total Leakage
BooleanuseLeakagePortfalseEnable leakage port, otherwise implicitly connected with tank
EfficiencyetaHm0.98Mechanical efficiency @ nRef, dpRef
RealnRef1000Reference speed (1/min)
AbsolutePressuredpRef2e+7Reference pressure difference
StateSelectstateSelectStateSelect.​preferPriority to use phi and w as states
BooleanforwardFluidPropertiestrueForward fluid properties between ports

Connectors

TypeNameDescription
FluidPortfluidPortAHydraulic port A
FluidPortfluidPortBHydraulic port B
Flange_aflange_a 
Flange_bflange_b 
FluidPortfluidPortLeakageHydraulic port Leakage

Model HydraulicsByFluidon.​Components.​Base.​SimpleDisplacementMachineTwoDir
Partial model for a component with two rotational 1-dim. shaft flanges

Information

Model of a simple displacement machine without losses.

The displacement machine is parameterised by providing its displacement volume dispVolume.

Extends from HydraulicsByFluidon.​Components.​Pumps.​Interfaces.​PartialPump (Partial Pump) and Modelica.​Mechanics.​Rotational.​Interfaces.​PartialTwoFlanges (Partial model for a component with two rotational 1-dim. shaft flanges).

Parameters

TypeNameDefaultDescription
BooleanforwardFluidPropertiestrueForward fluid properties between ports
VolumedispVolume5e-5Displacement volume of the machine

Connectors

TypeNameDescription
FluidPortfluidPortAHydraulic port A
FluidPortfluidPortBHydraulic port B
Flange_aflange_aFlange of left shaft
Flange_bflange_bFlange of right shaft

Partial Model HydraulicsByFluidon.​Components.​Base.​PartialReliefResistorBase

Information

The component PartialReliefResistorBase is the basic model of a flow resistance.

Extends from HydraulicsByFluidon.​Components.​Base.​HydTwoPortVertical.

Parameters

TypeNameDefaultDescription
BooleanforwardFluidPropertiestrueForward fluid properties between ports

Connectors

TypeNameDescription
FluidPortfluidPortAHydraulic port A
FluidPortfluidPortBHydraulic port B

Partial Model HydraulicsByFluidon.​Components.​Base.​PartialReliefResistor

Information

The component PartialReliefResistor is the basic model of a flow resistance that behaves either like an orifice or a throttle, depending on the parameter setting.

Flow is adjusted via the Input signal with nominal flow (as given by nominal flow/ nominal pressure difference) corresponding to an input value of 1.

Extends from HydraulicsByFluidon.​Components.​Base.​PartialReliefResistorBase.

Parameters

TypeNameDefaultDescription
BooleanforwardFluidPropertiestrueForward fluid properties between ports
VolumeFlowRateNominalVolumeFlow5e-4Nominal volume flow
PressureNominalPressureDifference500000Nominal pressure difference
DensityReferenceDensity860Reference density

Connectors

TypeNameDescription
FluidPortfluidPortAHydraulic port A
FluidPortfluidPortBHydraulic port B