Package Modelica.​Magnetic.​QuasiStatic.​FundamentalWave.​BasicMachines.​SynchronousMachines
Quasi static synchronous machines

Information

Standard package icon.

Extends from Modelica.​Icons.​Package (Icon for standard packages).

Package Contents

NameDescription
SM_ElectricalExcitedElectrical excited synchronous machine with optional damper cage
SM_PermanentMagnetPermanent magnet synchronous machine with optional damper cage
SM_ReluctanceRotorSynchronous reluctance machine with optional damper cage

Model Modelica.​Magnetic.​QuasiStatic.​FundamentalWave.​BasicMachines.​SynchronousMachines.​SM_PermanentMagnet
Permanent magnet synchronous machine with optional damper cage

Information

Resistances and stray inductances of the machine refer to an m phase stator. The symmetry of the stator and the supply are assumed. For rotor asymmetries can be taken into account by different resistances and stray inductances in the d- and q-axis. The machine models take the following loss effects into account:

See also

SM_ElectricalExcited, SM_ReluctanceRotor, Magnetic.FundamentalWave.BasicMachines.SM_PermanentMagnet, Magnetic.FundamentalWave.BasicMachines.SM_ElectricalExcited, Magnetic.FundamentalWave.BasicMachines.SM_ReluctanceRotor,

Extends from Modelica.​Magnetic.​QuasiStatic.​FundamentalWave.​BasicMachines.​BaseClasses.​PartialBasicMachine (Partial model for quasi static multi phase machines).

Parameters

TypeNameDefaultDescription
Integerm3Number of stator phases
InertiaJr Rotor inertia
BooleanuseSupportfalseEnable / disable (=fixed stator) support
InertiaJs Stator inertia
BooleanuseThermalPortfalseEnable / disable (=fixed temperatures) thermal port
Integerp Number of pole pairs (Integer)
FrequencyfsNominal Nominal frequency
TemperatureTsOperational Operational temperature of stator resistance
ResistanceRs Stator resistance per phase at TRef
TemperatureTsRef Reference temperature of stator resistance
LinearTemperatureCoefficient20alpha20s Temperature coefficient of stator resistance at 20 degC
RealeffectiveStatorTurns1Effective number of stator turns
InductanceLssigma Stator stray inductance per phase
SalientInductanceL0 Salient inductance of an unchorded coil
FrictionParametersfrictionParameters Friction loss parameter record
CoreParametersstatorCoreParameters Stator core loss parameter record; all parameters refer to stator side
StrayLoadParametersstrayLoadParameters Stray load loss parameter record
InductanceLmd Stator main field inductance per phase, d-axis
InductanceLmq Stator main field inductance per phase, q-axis
BooleanuseDamperCage Enable/disable damper cage
InductanceLrsigmad Rotor leakage inductance, d-axis, w.r.t. stator side
InductanceLrsigmaqLrsigmadRotor leakage inductance, q-axis, w.r.t. stator side
ResistanceRrd Rotor resistance, d-axis, w.r.t. stator side
ResistanceRrqRrdRotor resistance , q-axis, w.r.t. stator side
TemperatureTrRef Reference temperature of damper resistances in d- and q-axis
LinearTemperatureCoefficient20alpha20r Temperature coefficient of damper resistances in d- and q-axis
final TemperatureTpmOperational293.15Operational temperature of permanent magnet
TemperatureTrOperational Operational temperature of (optional) damper cage
VoltageVsOpenCircuit Open circuit RMS voltage per phase @ fsNominal
PermanentMagnetLossParameterspermanentMagnetLossParameters Permanent magnet loss parameter record

Connectors

TypeNameDescription
Flange_aflangeShaft
Flange_asupportSupport at which the reaction torque is acting
PositivePlugplug_spPositive plug of stator
NegativePlugplug_snNegative plug of stator
ThermalPortSMPMthermalPortThermal port of induction machines
ThermalPortSMPMinternalThermalPort 
SupportinternalSupport 
output ComplexOutputir[2]Damper cage currents

Model Modelica.​Magnetic.​QuasiStatic.​FundamentalWave.​BasicMachines.​SynchronousMachines.​SM_ElectricalExcited
Electrical excited synchronous machine with optional damper cage

Information

Resistances and stray inductances of the machine refer to an m phase stator. The symmetry of the stator and the supply are assumed. For rotor asymmetries can be taken into account by different resistances and stray inductances in the d- and q-axis. The machine models take the following loss effects into account:

See also

SM_PermanentMagnet, SM_ReluctanceRotor, Magnetic.FundamentalWave.BasicMachines.SM_PermanentMagnet, Magnetic.FundamentalWave.BasicMachines.SM_ElectricalExcited, Magnetic.FundamentalWave.BasicMachines.SM_ReluctanceRotor,

Extends from Modelica.​Magnetic.​QuasiStatic.​FundamentalWave.​BasicMachines.​BaseClasses.​PartialBasicMachine (Partial model for quasi static multi phase machines).

Parameters

TypeNameDefaultDescription
Integerm3Number of stator phases
InertiaJr Rotor inertia
BooleanuseSupportfalseEnable / disable (=fixed stator) support
InertiaJs Stator inertia
BooleanuseThermalPortfalseEnable / disable (=fixed temperatures) thermal port
Integerp Number of pole pairs (Integer)
FrequencyfsNominal Nominal frequency
TemperatureTsOperational Operational temperature of stator resistance
ResistanceRs Stator resistance per phase at TRef
TemperatureTsRef Reference temperature of stator resistance
LinearTemperatureCoefficient20alpha20s Temperature coefficient of stator resistance at 20 degC
RealeffectiveStatorTurns1Effective number of stator turns
InductanceLssigma Stator stray inductance per phase
SalientInductanceL0 Salient inductance of an unchorded coil
FrictionParametersfrictionParameters Friction loss parameter record
CoreParametersstatorCoreParameters Stator core loss parameter record; all parameters refer to stator side
StrayLoadParametersstrayLoadParameters Stray load loss parameter record
InductanceLmd Stator main field inductance per phase, d-axis
InductanceLmq Stator main field inductance per phase, q-axis
BooleanuseDamperCage Enable/disable damper cage
InductanceLrsigmad Rotor leakage inductance, d-axis, w.r.t. stator side
InductanceLrsigmaqLrsigmadRotor leakage inductance, q-axis, w.r.t. stator side
ResistanceRrd Rotor resistance, d-axis, w.r.t. stator side
ResistanceRrqRrdRotor resistance , q-axis, w.r.t. stator side
TemperatureTrRef Reference temperature of damper resistances in d- and q-axis
LinearTemperatureCoefficient20alpha20r Temperature coefficient of damper resistances in d- and q-axis
TemperatureTrOperational Operational temperature of (optional) damper cage
TemperatureTeOperational Operational excitation temperature
VoltageVsNominal Nominal stator voltage
CurrentIeOpenCircuit Open circuit excitation current @ nominal voltage and frequency
ResistanceRe Warm excitation resistance
TemperatureTeRef Reference temperature of excitation resistance
LinearTemperatureCoefficient20alpha20e Temperature coefficient of excitation resistance
BrushParametersbrushParameters Brush loss parameter record

Connectors

TypeNameDescription
Flange_aflangeShaft
Flange_asupportSupport at which the reaction torque is acting
PositivePlugplug_spPositive plug of stator
NegativePlugplug_snNegative plug of stator
ThermalPortSMEEthermalPortThermal port of induction machines
ThermalPortSMEEinternalThermalPort 
SupportinternalSupport 
output ComplexOutputir[2]Damper cage currents
PositivePinpin_epPositive pin of excitation
NegativePinpin_enNegative pin of excitation

Model Modelica.​Magnetic.​QuasiStatic.​FundamentalWave.​BasicMachines.​SynchronousMachines.​SM_ReluctanceRotor
Synchronous reluctance machine with optional damper cage

Information

Resistances and stray inductances of the machine refer to an m phase stator. The symmetry of the stator and the supply are assumed. For rotor asymmetries can be taken into account by different resistances and stray inductances in the d- and q-axis. The machine models take the following loss effects into account:

See also

SM_PermanentMagnet, SM_ElectricalExcited, Magnetic.FundamentalWave.BasicMachines.SM_PermanentMagnet, Magnetic.FundamentalWave.BasicMachines.SM_ElectricalExcited, Magnetic.FundamentalWave.BasicMachines.SM_ReluctanceRotor,

Extends from Modelica.​Magnetic.​QuasiStatic.​FundamentalWave.​BasicMachines.​BaseClasses.​PartialBasicMachine (Partial model for quasi static multi phase machines).

Parameters

TypeNameDefaultDescription
Integerm3Number of stator phases
InertiaJr Rotor inertia
BooleanuseSupportfalseEnable / disable (=fixed stator) support
InertiaJs Stator inertia
BooleanuseThermalPortfalseEnable / disable (=fixed temperatures) thermal port
Integerp Number of pole pairs (Integer)
FrequencyfsNominal Nominal frequency
TemperatureTsOperational Operational temperature of stator resistance
ResistanceRs Stator resistance per phase at TRef
TemperatureTsRef Reference temperature of stator resistance
LinearTemperatureCoefficient20alpha20s Temperature coefficient of stator resistance at 20 degC
RealeffectiveStatorTurns1Effective number of stator turns
InductanceLssigma Stator stray inductance per phase
SalientInductanceL0 Salient inductance of an unchorded coil
FrictionParametersfrictionParameters Friction loss parameter record
CoreParametersstatorCoreParameters Stator core loss parameter record; all parameters refer to stator side
StrayLoadParametersstrayLoadParameters Stray load loss parameter record
InductanceLmd Stator main field inductance per phase, d-axis
InductanceLmq Stator main field inductance per phase, q-axis
BooleanuseDamperCage Enable/disable damper cage
InductanceLrsigmad Rotor leakage inductance, d-axis, w.r.t. stator side
InductanceLrsigmaqLrsigmadRotor leakage inductance, q-axis, w.r.t. stator side
ResistanceRrd Rotor resistance, d-axis, w.r.t. stator side
ResistanceRrqRrdRotor resistance , q-axis, w.r.t. stator side
TemperatureTrRef Reference temperature of damper resistances in d- and q-axis
LinearTemperatureCoefficient20alpha20r Temperature coefficient of damper resistances in d- and q-axis
TemperatureTrOperational Operational temperature of (optional) damper cage

Connectors

TypeNameDescription
Flange_aflangeShaft
Flange_asupportSupport at which the reaction torque is acting
PositivePlugplug_spPositive plug of stator
NegativePlugplug_snNegative plug of stator
ThermalPortSMRthermalPortThermal port of induction machines
ThermalPortSMRinternalThermalPort 
SupportinternalSupport 
output ComplexOutputir[2]Damper cage currents