Package Modelica.​Magnetic.​QuasiStatic.​FundamentalWave.​Losses
Loss models

Information

Standard package icon.

Extends from Modelica.​Icons.​Package (Icon for standard packages).

Package Contents

NameDescription
PermanentMagnetLossesModel of permanent magnet losses dependent on current and speed
StrayLoadModel of stray load losses dependent on current and speed

Model Modelica.​Magnetic.​QuasiStatic.​FundamentalWave.​Losses.​StrayLoad
Model of stray load losses dependent on current and speed

Information

Stray load losses are modeled similar to standards EN 60034-2 and IEEE 512, i.e., they are dependent on square of current, but without scaling them to zero at no-load current.

For an estimation of dependency on varying angular velocity see: [Lang1984]

The stray load losses are modeled such way that they do not cause a voltage drop in the electric circuit. Instead, the dissipated losses are considered through an equivalent braking torque at the shaft.

The stray load loss torque is

  tau = PRef/wRef * (i/IRef)^2 * (w/wRef)^power_w

where i is the current of the machine and w is the actual angular velocity. The dependency of the stray load torque on the angular velocity is modeled by the exponent power_w.

See also

StrayLoad parameters

If it is desired to neglect stray load losses, set strayLoadParameters.PRef = 0 (this is the default).

Extends from Modelica.​Electrical.​QuasiStationary.​MultiPhase.​Interfaces.​OnePort, Modelica.​Electrical.​Machines.​Interfaces.​FlangeSupport (Shaft and support), and Modelica.​Thermal.​HeatTransfer.​Interfaces.​PartialElementaryConditionalHeatPortWithoutT (Partial model to include a conditional HeatPort in order to dissipate losses, used for textual modeling, i.e., for elementary models).

Parameters

TypeNameDefaultDescription
Integerm3Number of phases
StrayLoadParametersstrayLoadParameters Stray load loss parameters
BooleanuseHeatPortfalse=true, if heatPort is enabled

Connectors

TypeNameDescription
PositivePlugplug_pPositive quasi-static polyphase plug
NegativePlugplug_nNegative quasi-static polyphase plug
Flange_aflangeShaft end
Flange_asupportHousing and support
HeatPort_aheatPortOptional port to which dissipated losses are transported in form of heat

Model Modelica.​Magnetic.​QuasiStatic.​FundamentalWave.​Losses.​PermanentMagnetLosses
Model of permanent magnet losses dependent on current and speed

Information

Permanent magnet losses are modeled dependent on current and speed.

The permanent magnet losses are modeled such way that they do not cause a voltage drop in the electric circuit. Instead, the dissipated losses are considered through an equivalent braking torque at the shaft.

The permanent magnet loss torque is

  tau = PRef/wRef * (c + (1 - c) * (i/IRef)^power_I) * (w/wRef)^power_w

where i is the current of the machine and w is the actual angular velocity. The parameter c designates the part of the permanent magnet losses that are present even at current = 0, i.e. independent of current. The dependency of the permanent magnet loss torque on the stator current is modeled by the exponent power_I. The dependency of the permanent magnet loss torque on the angular velocity is modeled by the exponent power_w.

See also

Permanent magnet loss parameters

If it is desired to neglect permanent magnet losses, set strayLoadParameters.PRef = 0 (this is the default).

Extends from Modelica.​Electrical.​Machines.​Interfaces.​FlangeSupport (Shaft and support) and Modelica.​Thermal.​HeatTransfer.​Interfaces.​PartialElementaryConditionalHeatPortWithoutT (Partial model to include a conditional HeatPort in order to dissipate losses, used for textual modeling, i.e., for elementary models).

Parameters

TypeNameDefaultDescription
Integerm3Number of phases
PermanentMagnetLossParameterspermanentMagnetLossParameters Permanent magnet loss parameters
BooleanuseHeatPortfalse=true, if heatPort is enabled

Connectors

TypeNameDescription
Flange_aflangeShaft end
Flange_asupportHousing and support
HeatPort_aheatPortOptional port to which dissipated losses are transported in form of heat