ControlledCloserWithArc

Controlled ideal electrical closer with simple arc model

    ControlledCloserWithArc

Library

Electrical/Analog/Ideal

Description

This model is an extension to the ControlledIdealClosingSwitch.

For details of the arc effect, see partial model IdealSwitchWithArc.

Parameters

ControlledCloserWithArc_0

NameLabelDescriptionData TypeValid Values

mo_level

level

Switch level

Scalar

mo_Ron

Ron

Closed switch resistance

Scalar

mo_Goff

Goff

Opened switch conductance

Scalar

mo_V0

V0

Initial arc voltage

Scalar

mo_dVdt

dVdt

Arc voltage slope

Scalar

mo_Vmax

Vmax

Max. arc voltage

Scalar

mo_useHeatPort

useHeatPort

=true, if heatPort is enabled

Number

0
1

mo_T

T

Fixed device temperature if useHeatPort = false

Scalar

ControlledCloserWithArc_1

NameLabelDescriptionData TypeValid Values

mo_v

v

v

Structure

mo_v/fixed

fixed

Cell of scalars

true
false

mo_v/start

start

Cell of scalars

mo_i

i

i

Structure

mo_i/fixed

fixed

Cell of scalars

true
false

mo_i/start

start

Cell of scalars

mo_LossPower

LossPower

LossPower

Structure

mo_LossPower/fixed

fixed

Cell of scalars

true
false

mo_LossPower/start

start

Cell of scalars

mo_T_heatPort

T_heatPort

T_heatPort

Structure

mo_T_heatPort/fixed

fixed

Cell of scalars

true
false

mo_T_heatPort/start

start

Cell of scalars

mo_off

off

off

Structure

mo_off/fixed

fixed

Cell of scalars

true
false

mo_off/start

start

Cell of scalars

Ports

NameTypeDescriptionIO TypeNumber

p

implicit

Positive electrical pin

input

1

n

implicit

Negative electrical pin

output

1

control

implicit

Control pin: control.v > level switch closed, otherwise switch open

input

2

Port 4

implicit

Conditional heat port

input

mo_useHeatPort