RotorDisplacementAngle

Rotor lagging angle

    RotorDisplacementAngle

Library

Electrical/Machines/Sensors

Description

Calculates rotor lagging angle by measuring the stator phase voltages, transforming them to the corresponding space phasor in stator-fixed coordinate system,
rotating the space phasor to the rotor-fixed coordinate system and calculating the angle of this space phasor.

The sensor's housing can be implicitly fixed (useSupport=false).
If the machine's stator also implicitly fixed (useSupport=false), the angle at the flange is equal to the angle of the machine's rotor against the stator.
Otherwise, the sensor's support has to be connected to the machine's support.

Parameters

RotorDisplacementAngle_0

NameLabelDescriptionData TypeValid Values

mo_m

m

Number of phases

Scalar

mo_p

p

Number of pole pairs

Scalar

mo_positiveRange

positiveRange

Use only positive output range, if true

Scalar

true
false

mo_threshold

threshold

Below threshold the voltage is considered as zero

Scalar

mo_useSupport

useSupport

Use support or fixed housing

Number

0
1

RotorDisplacementAngle_1

NameLabelDescriptionData TypeValid Values

mo_rotorDisplacementAngle

rotorDisplacementAngle

rotorDisplacementAngle

Structure

mo_rotorDisplacementAngle/fixed

fixed

Cell of scalars

true
false

mo_rotorDisplacementAngle/start

start

Cell of scalars

Ports

NameTypeDescriptionIO TypeNumber

rotorDisplacementAngle

implicit

output

1

plug_p

implicit

input

1

plug_n

implicit

output

2

flange

implicit

input

2

Port 5

implicit

support at which the reaction torque is acting

input

mo_useSupport