DiodeBridge2mPulse

2*m pulse diode rectifier bridge

    DiodeBridge2mPulse

Library

Electrical/PowerConverters/ACDC

Description

General information about AC/DC converters can be found at the AC/DC converter concept

This is a 2*m pulse diode rectifier bridge. In order to operate this rectifier a voltage source with center tap is required. The circuit topology is the same as in Examples.ACDC.RectifierBridge2mPulse. It is important to note that for multi phase circuits with even phase numbers greater than three the MultiStarResistance shall be used for grounding the voltage sources.

Parameters

DiodeBridge2mPulse_0

NameLabelDescriptionData TypeValid Values

mo_m

m

Number of phases

Scalar

mo_RonDiode

RonDiode

Closed diode resistance

Scalar

mo_GoffDiode

GoffDiode

Opened diode conductance

Scalar

mo_VkneeDiode

VkneeDiode

Diode forward threshold voltage

Scalar

mo_useHeatPort

useHeatPort

=true, if heatPort is enabled

Number

0
1

mo_T

T

Fixed device temperature if useHeatPort = false

Scalar

DiodeBridge2mPulse_1

NameLabelDescriptionData TypeValid Values

mo_vAC

vAC

vAC

Structure

mo_vAC/fixed

fixed

Cell of vectors

true
false

mo_vAC/start

start

Cell of vectors

mo_iAC

iAC

iAC

Structure

mo_iAC/fixed

fixed

Cell of vectors

true
false

mo_iAC/start

start

Cell of vectors

mo_powerAC

powerAC

powerAC

Structure

mo_powerAC/fixed

fixed

Cell of vectors

true
false

mo_powerAC/start

start

Cell of vectors

mo_powerTotalAC

powerTotalAC

powerTotalAC

Structure

mo_powerTotalAC/fixed

fixed

Cell of scalars

true
false

mo_powerTotalAC/start

start

Cell of scalars

mo_vDC

vDC

vDC

Structure

mo_vDC/fixed

fixed

Cell of scalars

true
false

mo_vDC/start

start

Cell of scalars

mo_iDC

iDC

iDC

Structure

mo_iDC/fixed

fixed

Cell of scalars

true
false

mo_iDC/start

start

Cell of scalars

mo_powerDC

powerDC

powerDC

Structure

mo_powerDC/fixed

fixed

Cell of scalars

true
false

mo_powerDC/start

start

Cell of scalars

mo_LossPower

LossPower

LossPower

Structure

mo_LossPower/fixed

fixed

Cell of scalars

true
false

mo_LossPower/start

start

Cell of scalars

mo_T_heatPort

T_heatPort

T_heatPort

Structure

mo_T_heatPort/fixed

fixed

Cell of scalars

true
false

mo_T_heatPort/start

start

Cell of scalars

Ports

NameTypeDescriptionIO TypeNumber

ac

implicit

AC input

input

1

dc_p

implicit

Positive DC output

input

2

dc_n

implicit

Negative DC output

output

1

Port 4

implicit

Conditional heat port

input

mo_useHeatPort