Package Modelica.​Electrical.​PowerConverters.​ACDC
AC to DC converters

Information

General information about AC/DC converters can be found at the AC/DC converter concept

Extends from Modelica.​Icons.​Package (Icon for standard packages).

Package Contents

NameDescription
ControlControl components for rectifiers
DiodeBridge2mPulse2*m pulse diode rectifier bridge
DiodeBridge2PulseTwo pulse Graetz diode rectifier bridge
DiodeCenterTap2mPulse2*m pulse diode rectifier with center tap
DiodeCenterTap2PulseTwo pulse diode rectifier with center tap
DiodeCenterTapmPulsem pulse diode rectifier with center tap
HalfControlledBridge2mPulse2*m pulse half controlled rectifier bridge
HalfControlledBridge2PulseTwo pulse Graetz half controlled rectifier bridge
ThyristorBridge2mPulse2*m pulse thyristor rectifier bridge
ThyristorBridge2PulseTwo pulse Graetz thyristor rectifier bridge
ThyristorCenterTap2mPulse2*m pulse thyristor rectifier with center tap
ThyristorCenterTap2PulseTwo pulse thyristor rectifier with center tap
ThyristorCenterTapmPulsem pulse thyristor rectifier with center tap

Model Modelica.​Electrical.​PowerConverters.​ACDC.​DiodeBridge2Pulse
Two pulse Graetz diode rectifier bridge

Information

General information about AC/DC converters can be found at the AC/DC converter concept

This is a two pulse Graetz diode rectifier bridge. The circuit topology is the same as in Examples.ACDC.RectifierCenterTap2Pulse.

Extends from Modelica.​Electrical.​PowerConverters.​Icons.​Converter (Converter icon), Modelica.​Electrical.​PowerConverters.​Interfaces.​ACDC.​ACtwoPin (Positive and negative AC pin), Modelica.​Electrical.​PowerConverters.​Interfaces.​ACDC.​DCtwoPin (Positive and negative DC pins), and Modelica.​Electrical.​Analog.​Interfaces.​ConditionalHeatPort (Partial model to include a conditional HeatPort in order to describe the power loss via a thermal network).

Parameters

TypeNameDefaultDescription
ResistanceRonDiode1e-5Closed diode resistance
ConductanceGoffDiode1e-5Opened diode conductance
VoltageVkneeDiode0Diode forward threshold voltage
BooleanuseHeatPortfalse=true, if heatPort is enabled
final TemperatureT293.15Fixed device temperature if useHeatPort = false

Connectors

TypeNameDescription
PositivePinac_pPositive AC input
NegativePinac_nNegative AC input
PositivePindc_pPositive DC output
NegativePindc_nNegative DC output
HeatPort_aheatPortConditional heat port

Model Modelica.​Electrical.​PowerConverters.​ACDC.​ThyristorBridge2Pulse
Two pulse Graetz thyristor rectifier bridge

Information

General information about AC/DC converters can be found at the AC/DC converter concept

This is a two pulse Graetz thyristor rectifier bridge. The firing signal fire_p are connected with thyristor thyristor_p1 and thyristor_n2. The firing signal fire_n are connected with thyristor thyristor_p2 and thyristor_n1. See example Examples.ACDC.RectifierCenterTap2Pulse.

Extends from Modelica.​Electrical.​PowerConverters.​Icons.​Converter (Converter icon), Modelica.​Electrical.​PowerConverters.​Interfaces.​ACDC.​ACtwoPin (Positive and negative AC pin), Modelica.​Electrical.​PowerConverters.​Interfaces.​ACDC.​DCtwoPin (Positive and negative DC pins), Modelica.​Electrical.​Analog.​Interfaces.​ConditionalHeatPort (Partial model to include a conditional HeatPort in order to describe the power loss via a thermal network), and Modelica.​Electrical.​PowerConverters.​Interfaces.​Enable.​Enable2 (Partial model providing enable parameter and optional enable input for two firing signals).

Parameters

TypeNameDefaultDescription
ResistanceRonThyristor1e-5Closed thyristor resistance
ConductanceGoffThyristor1e-5Opened thyristor conductance
VoltageVkneeThyristor0Thyristor forward threshold voltage
BooleanoffStart_p1trueBoolean start value of variable thyristor_p1.off
BooleanoffStart_p2trueBoolean start value of variable thyristor_p2.off
BooleanoffStart_n1trueBoolean start value of variable thyristor_n1.off
BooleanoffStart_n2trueBoolean start value of variable thyristor_n2.off
BooleanuseHeatPortfalse=true, if heatPort is enabled
final TemperatureT293.15Fixed device temperature if useHeatPort = false
BooleanuseConstantEnabletruetrue = disabled boolean input, use constantEnable
BooleanconstantEnabletrueConstant enabling of firing signals
final Integerm1Number of phases

Connectors

TypeNameDescription
PositivePinac_pPositive AC input
NegativePinac_nNegative AC input
PositivePindc_pPositive DC output
NegativePindc_nNegative DC output
HeatPort_aheatPortConditional heat port
input BooleanInputenableEnables fire and notFire
input BooleanInputfire_pFiring signal of positive potential transistor
input BooleanInputfire_nFiring signal of negative potential transistor

Model Modelica.​Electrical.​PowerConverters.​ACDC.​HalfControlledBridge2Pulse
Two pulse Graetz half controlled rectifier bridge

Information

General information about AC/DC converters can be found at the AC/DC converter concept

This is a two pulse Graetz half controlled rectifier bridge. The firing signal fire_p is connected with thyristor thyristor_p1. The firing signal fire_n is connected with thyristor thyristor_p2. The circuit topology is the same as in Examples.ACDC.RectifierCenterTap2Pulse.

Extends from Modelica.​Electrical.​PowerConverters.​Icons.​Converter (Converter icon), Modelica.​Electrical.​PowerConverters.​Interfaces.​ACDC.​ACtwoPin (Positive and negative AC pin), Modelica.​Electrical.​PowerConverters.​Interfaces.​ACDC.​DCtwoPin (Positive and negative DC pins), Modelica.​Electrical.​Analog.​Interfaces.​ConditionalHeatPort (Partial model to include a conditional HeatPort in order to describe the power loss via a thermal network), and Modelica.​Electrical.​PowerConverters.​Interfaces.​Enable.​Enable2 (Partial model providing enable parameter and optional enable input for two firing signals).

Parameters

TypeNameDefaultDescription
ResistanceRonDiode1e-5Closed diode resistance
ConductanceGoffDiode1e-5Opened diode conductance
VoltageVkneeDiode0Diode forward threshold voltage
ResistanceRonThyristor1e-5Closed thyristor resistance
ConductanceGoffThyristor1e-5Opened thyristor conductance
VoltageVkneeThyristor0Thyristor forward threshold voltage
BooleanoffStart_p1trueBoolean start value of variable thyristor_p1.off
BooleanoffStart_p2trueBoolean start value of variable thyristor_p2.off
BooleanuseHeatPortfalse=true, if heatPort is enabled
final TemperatureT293.15Fixed device temperature if useHeatPort = false
BooleanuseConstantEnabletruetrue = disabled boolean input, use constantEnable
BooleanconstantEnabletrueConstant enabling of firing signals
final Integerm1Number of phases

Connectors

TypeNameDescription
PositivePinac_pPositive AC input
NegativePinac_nNegative AC input
PositivePindc_pPositive DC output
NegativePindc_nNegative DC output
HeatPort_aheatPortConditional heat port
input BooleanInputenableEnables fire and notFire
input BooleanInputfire_pFiring signal of positive potential transistor
input BooleanInputfire_nFiring signal of negative potential transistor

Model Modelica.​Electrical.​PowerConverters.​ACDC.​DiodeCenterTap2Pulse
Two pulse diode rectifier with center tap

Information

General information about AC/DC converters can be found at the AC/DC converter concept

This is a two pulse diode rectifier with center tap. In order to operate this rectifier a voltage with center tap is required. The center tap has to be connected with the negative pin of the load. The circuit topology is the same as in Examples.ACDC.RectifierCenterTap2Pulse.

Extends from Modelica.​Electrical.​PowerConverters.​Icons.​Converter (Converter icon), Modelica.​Electrical.​PowerConverters.​Interfaces.​ACDC.​ACtwoPin (Positive and negative AC pin), Modelica.​Electrical.​PowerConverters.​Interfaces.​ACDC.​DCpin (Single DC pin), and Modelica.​Electrical.​Analog.​Interfaces.​ConditionalHeatPort (Partial model to include a conditional HeatPort in order to describe the power loss via a thermal network).

Parameters

TypeNameDefaultDescription
ResistanceRonDiode1e-5Closed diode resistance
ConductanceGoffDiode1e-5Opened diode conductance
VoltageVkneeDiode0Diode forward threshold voltage
BooleanuseHeatPortfalse=true, if heatPort is enabled
final TemperatureT293.15Fixed device temperature if useHeatPort = false

Connectors

TypeNameDescription
PositivePinac_pPositive AC input
NegativePinac_nNegative AC input
PositivePindc_pPositive DC output
HeatPort_aheatPortConditional heat port

Model Modelica.​Electrical.​PowerConverters.​ACDC.​ThyristorCenterTap2Pulse
Two pulse thyristor rectifier with center tap

Information

General information about AC/DC converters can be found at the AC/DC converter concept

This a two pulse thyristor rectifier with center tap. In order to operate this rectifier a voltage with center tap is required. The center tap has to be connected with the negative pin of the load. The circuit topology is the same as in Examples.ACDC.RectifierCenterTap2Pulse.

Extends from Modelica.​Electrical.​PowerConverters.​Icons.​Converter (Converter icon), Modelica.​Electrical.​PowerConverters.​Interfaces.​ACDC.​ACtwoPin (Positive and negative AC pin), Modelica.​Electrical.​PowerConverters.​Interfaces.​ACDC.​DCpin (Single DC pin), Modelica.​Electrical.​Analog.​Interfaces.​ConditionalHeatPort (Partial model to include a conditional HeatPort in order to describe the power loss via a thermal network), and Modelica.​Electrical.​PowerConverters.​Interfaces.​Enable.​Enable2 (Partial model providing enable parameter and optional enable input for two firing signals).

Parameters

TypeNameDefaultDescription
ResistanceRonThyristor1e-5Closed thyristor resistance
ConductanceGoffThyristor1e-5Opened thyristor conductance
VoltageVkneeThyristor0Thyristor forward threshold voltage
BooleanoffStart_ptrueBoolean start value of variable thyristor_p.off
BooleanoffStart_ntrueBoolean start value of variable thyristor_n.off
BooleanuseHeatPortfalse=true, if heatPort is enabled
final TemperatureT293.15Fixed device temperature if useHeatPort = false
BooleanuseConstantEnabletruetrue = disabled boolean input, use constantEnable
BooleanconstantEnabletrueConstant enabling of firing signals
final Integerm1Number of phases

Connectors

TypeNameDescription
PositivePinac_pPositive AC input
NegativePinac_nNegative AC input
PositivePindc_pPositive DC output
HeatPort_aheatPortConditional heat port
input BooleanInputenableEnables fire and notFire
input BooleanInputfire_pFiring signal of positive potential transistor
input BooleanInputfire_nFiring signal of negative potential transistor

Model Modelica.​Electrical.​PowerConverters.​ACDC.​DiodeCenterTapmPulse
m pulse diode rectifier with center tap

Information

General information about AC/DC converters can be found at the AC/DC converter concept.

This is a m pulse diode rectifier with center tap. All voltage sources must have one interconnected plug (tap). This rectifiers works only with odd number of phases due the symmetry constrains of even phase numbers implemented in symmetricOrientation. The circuit topology is the same as in Examples.ACDC.RectifierCenterTapmPulse.

Extends from Modelica.​Electrical.​PowerConverters.​Icons.​Converter (Converter icon), Modelica.​Electrical.​PowerConverters.​Interfaces.​ACDC.​ACplug (AC multi phase plug), Modelica.​Electrical.​PowerConverters.​Interfaces.​ACDC.​DCpin (Single DC pin), and Modelica.​Electrical.​Analog.​Interfaces.​ConditionalHeatPort (Partial model to include a conditional HeatPort in order to describe the power loss via a thermal network).

Parameters

TypeNameDefaultDescription
Integerm3Number of phases
ResistanceRonDiode1e-5Closed diode resistance
ConductanceGoffDiode1e-5Opened diode conductance
VoltageVkneeDiode0Diode forward threshold voltage
BooleanuseHeatPortfalse=true, if heatPort is enabled
final TemperatureT293.15Fixed device temperature if useHeatPort = false

Connectors

TypeNameDescription
PositivePlugacAC input
PositivePindc_pPositive DC output
HeatPort_aheatPortConditional heat port

Model Modelica.​Electrical.​PowerConverters.​ACDC.​ThyristorCenterTapmPulse
m pulse thyristor rectifier with center tap

Information

General information about AC/DC converters can be found at the AC/DC converter concept

This is a m pulse thyristor rectifier with center tap. All voltage sources must have one interconnected plug (tap). This rectifiers works only with odd number of phases due the symmetry constrains of even phase numbers implemented in symmetricOrientation. See example Examples.ACDC.RectifierCenterTapmPulse.

Extends from Modelica.​Electrical.​PowerConverters.​Icons.​Converter (Converter icon), Modelica.​Electrical.​PowerConverters.​Interfaces.​ACDC.​ACplug (AC multi phase plug), Modelica.​Electrical.​PowerConverters.​Interfaces.​ACDC.​DCpin (Single DC pin), Modelica.​Electrical.​Analog.​Interfaces.​ConditionalHeatPort (Partial model to include a conditional HeatPort in order to describe the power loss via a thermal network), and Modelica.​Electrical.​PowerConverters.​Interfaces.​Enable.​Enable1m (Partial model providing enable parameter and optional enable input for m firing signals).

Parameters

TypeNameDefaultDescription
ResistanceRonThyristor1e-5Closed thyristor resistance
ConductanceGoffThyristor1e-5Opened thyristor conductance
VoltageVkneeThyristor0Thyristor forward threshold voltage
BooleanoffStart[m]fill(true, m)Boolean start value of variable thyristor_p[:].off
Integerm3Number of phases
BooleanuseHeatPortfalse=true, if heatPort is enabled
final TemperatureT293.15Fixed device temperature if useHeatPort = false
BooleanuseConstantEnabletruetrue = disabled boolean input, use constantEnable
BooleanconstantEnabletrueConstant enabling of firing signals

Connectors

TypeNameDescription
PositivePlugacAC input
PositivePindc_pPositive DC output
HeatPort_aheatPortConditional heat port
input BooleanInputfire_p[m]Firing signals of positive potential transistors
input BooleanInputenableEnables fire and notFire

Model Modelica.​Electrical.​PowerConverters.​ACDC.​DiodeBridge2mPulse
2*m pulse diode rectifier bridge

Information

General information about AC/DC converters can be found at the AC/DC converter concept

This is a 2*m pulse diode rectifier bridge. In order to operate this rectifier a voltage source with center tap is required. The circuit topology is the same as in Examples.ACDC.RectifierBridge2mPulse. It is important to note that for multi phase circuits with even phase numbers greater than three the MultiStarResistance shall be used for grounding the voltage sources.

Extends from Modelica.​Electrical.​PowerConverters.​Icons.​Converter (Converter icon), Modelica.​Electrical.​PowerConverters.​Interfaces.​ACDC.​ACplug (AC multi phase plug), Modelica.​Electrical.​PowerConverters.​Interfaces.​ACDC.​DCtwoPin (Positive and negative DC pins), and Modelica.​Electrical.​Analog.​Interfaces.​ConditionalHeatPort (Partial model to include a conditional HeatPort in order to describe the power loss via a thermal network).

Parameters

TypeNameDefaultDescription
Integerm3Number of phases
ResistanceRonDiode1e-5Closed diode resistance
ConductanceGoffDiode1e-5Opened diode conductance
VoltageVkneeDiode0Diode forward threshold voltage
BooleanuseHeatPortfalse=true, if heatPort is enabled
final TemperatureT293.15Fixed device temperature if useHeatPort = false

Connectors

TypeNameDescription
PositivePlugacAC input
PositivePindc_pPositive DC output
NegativePindc_nNegative DC output
HeatPort_aheatPortConditional heat port

Model Modelica.​Electrical.​PowerConverters.​ACDC.​ThyristorBridge2mPulse
2*m pulse thyristor rectifier bridge

Information

General information about AC/DC converters can be found at the AC/DC converter concept

This is a 2*m pulse thyristor rectifier bridge. In order to operate this rectifier a voltage source with center tap is required. It is important to note that for multi phase circuits with phase even phase numbers greater than three the MultiStarResistance shall be used for grounding the voltage sources. See example Examples.ACDC.RectifierBridge2mPulse.

Extends from Modelica.​Electrical.​PowerConverters.​Icons.​Converter (Converter icon), Modelica.​Electrical.​PowerConverters.​Interfaces.​ACDC.​ACplug (AC multi phase plug), Modelica.​Electrical.​PowerConverters.​Interfaces.​ACDC.​DCtwoPin (Positive and negative DC pins), Modelica.​Electrical.​Analog.​Interfaces.​ConditionalHeatPort (Partial model to include a conditional HeatPort in order to describe the power loss via a thermal network), and Modelica.​Electrical.​PowerConverters.​Interfaces.​Enable.​Enable2m (Partial model providing enable parameter and optional enable input for 2*m firing signals).

Parameters

TypeNameDefaultDescription
ResistanceRonThyristor1e-5Closed thyristor resistance
ConductanceGoffThyristor1e-5Opened thyristor conductance
VoltageVkneeThyristor0Thyristor forward threshold voltage
BooleanoffStart_p[m]fill(true, m)Boolean start value of variable thyristor_p[:].off
BooleanoffStart_n[m]fill(true, m)Boolean start value of variable thyristor_n[:].off
Integerm3Number of phases
BooleanuseHeatPortfalse=true, if heatPort is enabled
final TemperatureT293.15Fixed device temperature if useHeatPort = false
BooleanuseConstantEnabletruetrue = disabled boolean input, use constantEnable
BooleanconstantEnabletrueConstant enabling of firing signals

Connectors

TypeNameDescription
PositivePlugacAC input
PositivePindc_pPositive DC output
NegativePindc_nNegative DC output
HeatPort_aheatPortConditional heat port
input BooleanInputfire_p[m]Firing signals of positive potential transistors
input BooleanInputenableEnables fire and notFire
input BooleanInputfire_n[m]Firing signals of negative potential transistors

Model Modelica.​Electrical.​PowerConverters.​ACDC.​HalfControlledBridge2mPulse
2*m pulse half controlled rectifier bridge

Information

General information about AC/DC converters can be found at the AC/DC converter concept

This is a 2*m pulse half controlled rectifier bridge. In order to operate this rectifier a voltage source with center tap is required. The circuit topology is the same as in Examples.ACDC.RectifierBridge2mPulse. It is important to note that for multi phase circuits with even phase numbers greater than three the MultiStarResistance shall be used for grounding the voltage sources.

Extends from Modelica.​Electrical.​PowerConverters.​Icons.​Converter (Converter icon), Modelica.​Electrical.​PowerConverters.​Interfaces.​ACDC.​ACplug (AC multi phase plug), Modelica.​Electrical.​PowerConverters.​Interfaces.​ACDC.​DCtwoPin (Positive and negative DC pins), Modelica.​Electrical.​Analog.​Interfaces.​ConditionalHeatPort (Partial model to include a conditional HeatPort in order to describe the power loss via a thermal network), and Modelica.​Electrical.​PowerConverters.​Interfaces.​Enable.​Enable1m (Partial model providing enable parameter and optional enable input for m firing signals).

Parameters

TypeNameDefaultDescription
ResistanceRonDiode1e-5Closed diode resistance
ConductanceGoffDiode1e-5Opened diode conductance
VoltageVkneeDiode0Diode forward threshold voltage
ResistanceRonThyristor1e-5Closed thyristor resistance
ConductanceGoffThyristor1e-5Opened thyristor conductance
VoltageVkneeThyristor0Thyristor forward threshold voltage
BooleanoffStart_p[m]fill(true, m)Boolean start value of variable thyristor_p[:].off
Integerm3Number of phases
BooleanuseHeatPortfalse=true, if heatPort is enabled
final TemperatureT293.15Fixed device temperature if useHeatPort = false
BooleanuseConstantEnabletruetrue = disabled boolean input, use constantEnable
BooleanconstantEnabletrueConstant enabling of firing signals

Connectors

TypeNameDescription
PositivePlugacAC input
PositivePindc_pPositive DC output
NegativePindc_nNegative DC output
HeatPort_aheatPortConditional heat port
input BooleanInputfire_p[m]Firing signals of positive potential transistors
input BooleanInputenableEnables fire and notFire

Model Modelica.​Electrical.​PowerConverters.​ACDC.​DiodeCenterTap2mPulse
2*m pulse diode rectifier with center tap

Information

General information about AC/DC converters can be found at the AC/DC converter concept

This is a 2*m pulse diode rectifier with center tap. In order to operate this rectifier a voltage source with center tap is required. The center tap has to be connected with the negative pin of the load. The circuit topology is the same as in Examples.ACDC.RectifierCenterTap2mPulse.

Extends from Modelica.​Electrical.​PowerConverters.​Icons.​Converter (Converter icon), Modelica.​Electrical.​PowerConverters.​Interfaces.​ACDC.​ACtwoPlug (Two AC multi phase plugs), Modelica.​Electrical.​PowerConverters.​Interfaces.​ACDC.​DCpin (Single DC pin), and Modelica.​Electrical.​Analog.​Interfaces.​ConditionalHeatPort (Partial model to include a conditional HeatPort in order to describe the power loss via a thermal network).

Parameters

TypeNameDefaultDescription
Integerm3Number of phases
ResistanceRonDiode1e-5Closed diode resistance
ConductanceGoffDiode1e-5Opened diode conductance
VoltageVkneeDiode0Diode forward threshold voltage
BooleanuseHeatPortfalse=true, if heatPort is enabled
final TemperatureT293.15Fixed device temperature if useHeatPort = false

Connectors

TypeNameDescription
PositivePlugac_pPositive potential AC input
NegativePlugac_nNegative potential AC input
PositivePindc_pPositive DC output
HeatPort_aheatPortConditional heat port

Model Modelica.​Electrical.​PowerConverters.​ACDC.​ThyristorCenterTap2mPulse
2*m pulse thyristor rectifier with center tap

Information

General information about AC/DC converters can be found at the AC/DC converter concept

This is a 2*m pulse thyristor rectifier with center tap. In order to operate this rectifier a voltage source with center tap is required. The center tap has to be connected with the negative pin of the load. See example Examples.ACDC.RectifierCenterTap2mPulse.

Extends from Modelica.​Electrical.​PowerConverters.​Icons.​Converter (Converter icon), Modelica.​Electrical.​PowerConverters.​Interfaces.​ACDC.​ACtwoPlug (Two AC multi phase plugs), Modelica.​Electrical.​PowerConverters.​Interfaces.​ACDC.​DCpin (Single DC pin), Modelica.​Electrical.​Analog.​Interfaces.​ConditionalHeatPort (Partial model to include a conditional HeatPort in order to describe the power loss via a thermal network), and Modelica.​Electrical.​PowerConverters.​Interfaces.​Enable.​Enable2m (Partial model providing enable parameter and optional enable input for 2*m firing signals).

Parameters

TypeNameDefaultDescription
ResistanceRonThyristor1e-5Closed thyristor resistance
ConductanceGoffThyristor1e-5Opened thyristor conductance
VoltageVkneeThyristor0Thyristor forward threshold voltage
BooleanoffStart_p[m]fill(true, m)Boolean start value of variable thyristor_p[:].off
BooleanoffStart_n[m]fill(true, m)Boolean start value of variable thyristor_n[:].off
Integerm3Number of phases
BooleanuseHeatPortfalse=true, if heatPort is enabled
final TemperatureT293.15Fixed device temperature if useHeatPort = false
BooleanuseConstantEnabletruetrue = disabled boolean input, use constantEnable
BooleanconstantEnabletrueConstant enabling of firing signals

Connectors

TypeNameDescription
PositivePlugac_pPositive potential AC input
NegativePlugac_nNegative potential AC input
PositivePindc_pPositive DC output
HeatPort_aheatPortConditional heat port
input BooleanInputfire_p[m]Firing signals of positive potential transistors
input BooleanInputenableEnables fire and notFire
input BooleanInputfire_n[m]Firing signals of negative potential transistors