Submitting a Job
Define and run an analyis using the Run Analysis tool.
Analysis Parameters Settings
- Project name
- The data deck is written with "name" as a prefix. It is written in the same folder where the model is saved. Avoid using special characters as files will be created using this name.
- Solution Parameters
-
- Drape Analysis
- Enable to perform drape analysis.
- Vacuum Effects
- Enable to observe vacuum effects.
- Stop After
-
- Filling
- The simulation will be stopped once the model is completely filled. This is a useful option to understand how the model is filled.
- Curing
- The simulation continues after the model is filled and stops when all of the nodes reach the curing gelation point.
- Time
- The simulation will be stopped after the specified time amount of times elapses.
- Mesh Size
- Medium is the preferred option. If the model has many fine features, selecting Fine is recommended. If it is a simple model, Coarse option can be used. To start from existing mesh, click on Existing and select the mesh file. To specify mesh size by part, click on User-defined, then click the Mesh size tab and adjust default mesh sizes. On the Mesh size tab you can also elect to Use layered tetrahedral mesh and specify the Number of tetrahedral layers.
- Advanced Parameters
- Note: Must be enabled in Preferences to see these options.
Max Non Linear Iterations Maximum iterations per time step. Nonlinear iteration loops stop when the convergence criterion set by Nonlinear Iteration Tolerance is met. If the solution is not convergent, the loop will stop when it reaches this maximum value. The default value is 25.
Non Linear Iteration Tol Tolerance for nonlinear iterations. The default value is 0.001. This value defines the convergence criteria for nonlinear iterations.
For a fast and reasonably accurate analysis, nonlinear iteration tolerance can be increased to 0.005 or even 0.01.