Apply a waveguide port to a face.
-
On the Source/Load tab, in the
Ports group, click the Waveguide Port icon.
-
Click the Specification tab.
-
In the Face field, use point entry to specify the face
using one of the following workflows:
- In the 3D view, click on the relevant face.
- In the details tree, click on the relevant
face.
A propagation direction and reference direction are automatically
defined.
If the propagation direction is not correct, you can change the
direction.
-
[Optional] Clear the Propagation direction opposite to
normal check box to change the propagation direction to be in
the same direction as the normal.
If the reference vector is not correct, you can specify the reference
vector.
-
[Optional] Under Reference vector, specify the reference
vector.
-
[Optional] If the polarity of the port is to be reversed, select the
Reverse polarity check box.
-
In the Label field, add a unique label for the waveguide
port.
-
Click the Advanced tab.
When the number of modes to be considered is not specified, Feko calculates the number automatically.
-
[Optional] To specify the number of modes, click the Manually set
the maximum modal expansion indices check box.
-
Click Create to create the wire port and to close
the dialog.