Ramp Pulse
Define a ramp time pulse.
Figure 1. Define a ramp time pulse.
- Time axis unit
 - Specify the unit to be used for the time axis.
 - Total signal duration ( )
 - The total length of the signal in the specified units.
 - Amplitude ( )
 - The amplitude of the time signal.
 - Pulse delay ( )
 - The pulse delay is the time until the peak of the time signal envelope.
 - Pulse width ( )
 - This is the half-amplitude pulse width of the signal. The pulse width is the total length of time that the signal is above 50% of its peak value ( ).
 - Rise time ( )
 - The time required for the pulse to reach its peak value ( ) from rest.
 - Fall time ( )
 - The time required for the pulse to reach the rest value from its peak (
                                
                            ). Note: The discharge time will be determined by the pulse width ( ).
 - Number of samples
 - The number of samples taken from the signal’s analytical equation.
 
The Fourier transform is as follows: