FrequencyFDTDSettings
Advanced FDTD time interval properties.
Example
application = cf.Application.getInstance() project = application:NewProject() -- Enable the FDTD solver project.Contents.SolutionSettings.SolverSettings.FDTDSettings.FDTDEnabled = true -- Set the initial frequency frequency = project.Contents.SolutionConfigurations.GlobalFrequency frequency.Start = 100e6 -- Modify the FDTD time interval settings -- A properties table is used as both the modifications -- must be done together properties = frequency:GetProperties() properties.Advanced.FDTD.TimeIntervalType = cf.Enums.FrequencyFDTDTimeIntervalTypeEnum.Seconds properties.Advanced.FDTD.MaximumTimeIntervalEnabled = true properties.Advanced.FDTD.MaximumTimeInterval = 1e-5 frequency:SetProperties(properties)
Inheritance
The FrequencyFDTDSettings object is derived from the CompositeValue object.
Usage locations
The FrequencyFDTDSettings object can be accessed from the following locations:
- Properties
- FrequencyAdvancedSettings object has property FDTD.
- Methods
- FrequencyFDTDSettingsList object has method append().
- FrequencyFDTDSettingsList object has method get(number).
Property List
- ConvergenceThreshold
- Specify a value between (0,1). The simulation will be terminated if the threshold has been reached and the simulation time is larger or equal to the MinimumTimeInterval. Only valid if ConvergenceThresholdEnabled. (Read/Write ParametricExpression)
- ConvergenceThresholdEnabled
- Apply a convergence threshold. (Read/Write boolean)
- MaximumTimeInterval
- Set the maximum time interval duration for which the model is simulated. Only valid if MaximumTimeIntervalEnabled and TimeIntervalType is Periods or Seconds, which implies a unit of either (dimensionless) or (s). (Read/Write ParametricExpression)
- MaximumTimeIntervalEnabled
- Apply a maximum limit to the time interval duration.Only valid if TimeIntervalType is Periods or Seconds. (Read/Write boolean)
- MinimumTimeInterval
- Set the minimum time interval duration for which the model is simulated. Only valid if MinimumTimeIntervalEnabled and TimeIntervalType is Periods or Seconds, which implies a unit of either (dimensionless) or (s). (Read/Write ParametricExpression)
- MinimumTimeIntervalEnabled
- Apply a minimum limit to the time interval duration.Only valid if TimeIntervalType is Periods or Seconds. (Read/Write boolean)
- TimeIntervalType
- Control the determination of the time duration for which the model is simulated. (Read/Write FrequencyFDTDTimeIntervalTypeEnum)
Property Details
- ConvergenceThreshold
- Specify a value between (0,1). The simulation will be terminated if the threshold has been reached and the simulation time is larger or equal to the MinimumTimeInterval. Only valid if ConvergenceThresholdEnabled.
- Type
- ParametricExpression
- Access
- Read/Write
- ConvergenceThresholdEnabled
- Apply a convergence threshold.
- Type
- boolean
- Access
- Read/Write
- MaximumTimeInterval
- Set the maximum time interval duration for which the model is simulated. Only valid if MaximumTimeIntervalEnabled and TimeIntervalType is Periods or Seconds, which implies a unit of either (dimensionless) or (s).
- Type
- ParametricExpression
- Access
- Read/Write
- MaximumTimeIntervalEnabled
- Apply a maximum limit to the time interval duration.Only valid if TimeIntervalType is Periods or Seconds.
- Type
- boolean
- Access
- Read/Write
- MinimumTimeInterval
- Set the minimum time interval duration for which the model is simulated. Only valid if MinimumTimeIntervalEnabled and TimeIntervalType is Periods or Seconds, which implies a unit of either (dimensionless) or (s).
- Type
- ParametricExpression
- Access
- Read/Write
- MinimumTimeIntervalEnabled
- Apply a minimum limit to the time interval duration.Only valid if TimeIntervalType is Periods or Seconds.
- Type
- boolean
- Access
- Read/Write
- TimeIntervalType
- Control the determination of the time duration for which the model is simulated.
- Type
- FrequencyFDTDTimeIntervalTypeEnum
- Access
- Read/Write