Duty cycle
User working point(s) analysis = Duty cycle
This allows computing the machine performance all over a considered duty cycle.
This duty cycle must be defined by using the next field: "Duty cycle description" and by clicking on the button "Set values".
Two ways are possible to fill in the table: either filling in the table line by line or by importing an excel file which all the working points of the duty cycle are defined.
|  | |
| User working point analysis = Duty cycle | |
| 1 | Select the “Duty cycle” option | 
| 2 | Click in the button “Set values” of the field “Duty cycle” to open a dialog box to define the duty cycle.Refer to the next illustration which shows how to fill the Duty cycle table. | 
| 3 | Button to validate the user input data | 
| 4 | Button to run the computations | 
|  | |
| User working point analysis = Duty cycle – Dialog box to define the duty cycle | |
| 1 | Dialog box opened after having clicking the button “Set values” in the field “Cycle description” | 
| 2 | Browse the folder to select an Excel file which is described the duty cycle | 
| 3 | Button to refresh the table data when the considered Excel file has been modified | 
| 4 | Fields to be filled with data to describe the duty cycle to be considered | 
|  | 
| Excel file template to define the duty cycle |