Transient Magnetic: solved equations (introduction)
Introduction
The equations used for the solving are:
- Maxwell's equations (for a magnetic system)
- the constitutive equations of the matter
The computation conditions for a Transient Magnetic application are the following:
- the state variables are time dependent: d/dt ≠ 0 (transient or variable state: current sources vary with time)
- the computation concerns only the B, H and E fields (the D field is not computed). The equations of the electric fields E and D and of the magnetic fields B, H can't be decoupled.
Equations and conditions
In the previously defined conditions of computation, the equations are summarized as follows:
E : electric field strength (in V/m) B: magnetic flux density (in T) H: magnetic field strength (in A/m) J: current density (in A/m2) |
||||
σ : conductivity (in S) μ : permeability (in H/m) |
The principal equation for magnetic materials, can be put in form B(H) or H(B) as presented below.
⇒ |
μr : perméabilité relative μ0 : perméabilité du vide Br : induction rémanente (aimants) |
⇒ |
νr : reluctivity νr =1/μr ν0 : vacuum reluctivity ν0 =1/μ0 Hc : coercive magnetic field (permanent magnets) |
Models
To solve these equations, two models are used:
-
the vector model, which uses:
the magnetic vector potential (written )
-
the scalar model, which uses:
magnetic scalar potentials (written ϕtot or ϕred)
Model and 2D or 3D application
For 2D applications, the vector model is available by default.