Display Options
Customize plots using the following options
- Display
 - Do not show phase - Hides the phase values on the plot.
 - Scale
 - The following options are available under Scale:
- Linear
 - Plots the linear values.
 - Logarithmic
 - Plots the values in logarithmic scale. With this scale, data points are spread out more, which makes it easier to view.
 - % Plot
 - Plots the contribution of the selected modes as a percentage of the total response. Percentage plot is a good option to use when comparing contributors versus the total response.
 - dB10
 - 10 logarithmic of the participation value over the reference value.
 - dB20
 - 20 logarithmic of the participation value over the reference value. For acoustic responses, the reference pressure is 20E-12 MPa.
 - Weighting
 - A – A-weighting used to define equal loudness sound pressure levels.
 - Octave Band
 - Three menus allow you to customize the plot's octave band.
                                        Select an octave band from the left-most drop-down menu:
- Octave
 - 1/3 Octave
 - 1/6 Octave
 - 1/8 Octave
 - 1/12 Octave
 
Select Bar Plot or Line Curve as the octave plot type from the middle drop-down menu.
Select Sum, Integration, or Average as the Octave Magnitude from the right-most drop-down menu.
Note: This option is only available for Radiated Sound. 
 - Unit
 - Display unit information in the axes labels.
 - Plot Layout
 - Allows you to select how the plot window is displayed.
- New windows on current page
 - Plot is placed into a new window on the current page.
 - Active window
 - Plot is placed into the active window.
 - New windows on new page
 - Plot is placed into a new window on a new page.
 
 

Figure 1.