/IMPL/DYNA/DAMP

Engine Keyword Rayleigh structure damping with dynamic implicit analysis.

Format

/IMPL/DYNA/DAMP

α β

Definition

Field Contents SI Unit Example
α Coefficient  
β Coeffcient  

Comments

  1. Rayleigh damping computation:(1)
    C=αM+βK MathType@MTEF@5@5@+=feaagKart1ev2aqatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLnhiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr4rNCHbGeaGqiVu0Je9sqqrpepC0xbbL8F4rqqrFfpeea0xe9Lq=Jc9vqaqpepm0xbba9pwe9Q8fs0=yqaqpepae9pg0FirpepeKkFr0xfr=xfr=xb9adbaqaaeGaciGaaiaabeqaamaabaabaaGcbaGaaC4qaiabg2da9iabeg7aHjaah2eacqGHRaWkcqaHYoGycaWHlbaaaa@3D95@