SS-V: 3050 Table Frame

Test No. VT06Find temperature at points A, B, C, and D of an eight tube assembly.

Definition



Figure 1.

The model is a hollow tubular frame with dimmensions 2.25 x 1.5 x 1.5 m.

The units are SI.

The material properties are:
Properties
Value
Material
AISI Steel

Results

The following table summarizes the temperature at the four points of interest.
Location Reference SimSolid % Difference
A 110.2 112.1 1.72%
B 182.0 180.6 -0.77%
C 107.6 109.3 1.58%
D 143 143 0.00%
1 LM-TH-1 Learning Module 1, Thermal Analysis, Dr. Jack Xin, Dr. Liang-Wu Cai, www.femlearning.org, 2010.