ACU-T: 6500 Flow Through Porous Medium

Prerequisites

This tutorial provides the instructions for setting up, solving and viewing results for simulation of flow through a porous medium. Prior to starting this tutorial, you should have already run through the introductory tutorial, ACU-T: 1000 HyperWorks UI Introduction, and have a basic understanding of AcuSolve, HyperView, and HyperMesh. To run this simulation, you will need access to a licensed version of HyperMesh and AcuSolve.

Before you begin, copy the file(s) used in this tutorial to your working directory.

Since the HyperMesh database (.hm file) contains meshed geometry, this tutorial does not include steps related to geometry import and mesh generation.

Problem Description

The problem to be addressed in this tutorial is shown schematically in the figure below. It consists of a cylindrical channel with a porous medium in the flow section. As the flow passes through this section, a pressure drop is observed. In this simulation, an inlet velocity will be assigned to the flow and pressure drop across the porous medium will be calculated. The length of the porous section is 0.06 m and the fluid is an imaginary air-like fluid with a density of 1 kg/m3 and a molecular viscosity of 0.001 kg/m-s. The inlet velocity of the flow is 0.2 m/s.



Figure 1.

Open the HyperMesh Model Database

  1. Start HyperMesh and load the AcuSolve user profile.
    Refer to the HM introductory tutorial, ACU-T: 1000 HyperWorks UI Introduction, to learn how to select AcuSolve from User Profiles.
  2. Click the Open Model icon located on the standard toolbar.
    The Open Model dialog opens.
  3. Browse to the directory where you saved the model file. Select the HyperMesh file ACU-T6500_PorousMedia.hm and click Open.
  4. Click File > Save As.
    The Save Model As dialog opens.
  5. Create a new directory named PorousMedia and navigate into this directory.
    This will be the working directory and all the files related to the simulation will be stored in this location.
  6. Enter PorousMedia as the file name for the database, or choose any name of your preference.
  7. Click Save to create the database.

Set the General Simulation Parameters

In this step, you will set the simulation parameters that apply globally to the simulation.

  1. Go to the Solver Browser, expand 01.Global, then click PROBLEM_DESCRIPTION.
  2. In the Entity Editor, verify that the Analysis type is set to Steady State and the Turbulence model is set to Laminar.


    Figure 2.

Set Up Boundary Conditions and Material Model Parameters

In this step, you will start by modifying the material properties of Air and then create a material model for the porous medium. Then, you will assign the surface boundary conditions and material properties for all the fluid volumes.

Create the Material Model

  1. In the Solver Browser, expand 02.Materials > FLUID then click on Air_HM.
  2. In the Entity Editor, change the Density to 1 kg/m3 and the Viscosity to 0.001 kg/m-sec.


    Figure 3.
  3. Right-click on Air_HM in the Solver Browser and select Duplicate.
  4. Name the new material Porous.
  5. In the Entity Editor, scroll down to the Porosity tab and set the Porosity type to Constant.
  6. Enter the values 1, 0.001, and 0.001 for the Direction 1 permeability, Direction 2 permeability and Direction 3 permeability, respectively.
  7. Set the value of Darcy coefficient to 4166.67.
  8. Set the Forchheimer coefficient to 8.33.


    Figure 4.
  9. Save the model.

Assign Boundary Conditions and Material Properties

By default, all components are assigned to the wall boundary condition. In this step, you will change them to the appropriate boundary conditions and assign material properties to the fluid volumes.
  1. In the Solver Browser, expand 12.Surfaces > WALL.
  2. Click Inlet. In the Entity Editor,
    1. Change the Type to INFLOW.
    2. Set the Inflow velocity type to Cartesian.
    3. Set the X velocity to 0.2 m/sec


    Figure 5.
  3. Click Outlet. In the Entity Editor, change the Type to OUTFLOW.


    Figure 6.
  4. Click Walls. In the Entity Editor, verify that the Type is set to WALL.


    Figure 7.

    All the internal surfaces, such as the inlet and outlet of the porous section and the external walls of pipe surface, can be grouped into one single surface set. Auto_Wall, which is an advanced feature in AcuSolve, re-groups these elements into internal and external surfaces for each volume and writes the surface output accordingly. This process is done internally, thereby reducing the number of steps in the workflow.

  5. Click Fluid_Upstream. In the Entity Editor,
    1. Change the Type to FLUID.
    2. Select Air_HM as the Material.


    Figure 8.
  6. Click Fluid_Porous. In the Entity Editor,
    1. Change the Type to FLUID.
    2. Select Porous as the Material.


    Figure 9.
  7. Click Fluid_Downstream. In the Entity Editor,
    1. Change the Type to FLUID.
    2. Select Air_Hm as the Material.


    Figure 10.
  8. Save the model.

Compute the Solution

In this step, you will launch AcuSolve directly from HyperMesh and compute the solution.

  1. Turn on the visibility of all mesh components.
    For the analysis to run, the mesh for all active components must be visible.
  2. Click on the ACU toolbar.
    The Solver job Launcher dialog opens.
  3. Optional: For a faster solution time, set the number of processors to a higher number (4 or 8) based on availability.
  4. The Output time steps can be set to All or Final. Since this is a steady state analysis, the Final time step output is sufficient.
  5. Leave the remaining options as default and click Launch to start the solution process.


    Figure 11.

Post-Process the Results with HyperGraph

  1. Click the client selector in the bottom-left corner of the graphics area then select HyperGraph 2D.


    Figure 12.
  2. Once the HyperGraph interface loads, click in the panel area and select the result file from the current working directory.
    In this example, the file to be selected is PorousMedia.1.Log.
  3. Make sure that the X Type is set to Time, the Y Type to Pressure(surface), and the Y Request to AUTOFluid_Porous internal.


    Figure 13.
  4. Click Apply to display the first plot.
  5. Change the Y Request to AUTOFluid_Downstream internal.
  6. Click Apply again to display the second plot.


    Figure 14.

    The pressure difference between the porous inlet (AUTO Fluid_Porous Internal -pressure) and the porous outlet (AUTO Fluid_Downstream_internal-pressure) is 0.087 Pa.

Summary

In this tutorial, you learned how to set up and solve a problem with porous medium. You started by importing the HyperMesh database and then creating a material model for the porous section. Then, you assigned the boundary conditions and material properties and solved by launching AcuSolve directly from HyperMesh. Finally, you created a pressure drop plot using HyperGraph and calculated the drop in pressure between the inlet and outlet surfaces of the porous section.