Each design point set can have a different set of methods (design point method
        entity) assigned to it.
        
            You can add methods using the 
context menu on a design point
                set. This opens a dialog with a list of all of the registered functions. Methods are
                registered by category. When you add methods from a list, a new entity design point
                method is added as a child of the design point set. Certification methods can be one
                of the following:
                    
                        - INTERNAL
 
                        - Hard-coded method in HyperMesh. Not
                            customizable.
 
                    
                    
                        - DLL
 
                        - External dynamic library with methods exposed as EXTERN.
 
                    
                    
                        - COMPOSE
 
                        - Compose mathematical scripting language
                                (*.oml files).
 
                    
                    
                        - PYTHON
 
                        - Python functions.
 
                    
                    
                        - TCL
 
                        - Pure Tcl (procedures).
                                HyperMesh API's are not available.
 
                    
                
 
            All design points inside a design point set will be evaluated by all methods added to
                it. There are a set of pre-defined methods included with the installation located in
                an 
.xml file. You can copy this
                file from the installation in your directory and append your own methods.
Note: At
                    this stage, the 
HyperMesh model is fully
                    instrumented. Remaining parameters will be runtime settings. The file can be
                    saved as a binary file (
*.hm). The binary file contains
                    everything to restore a ready to run database. 
The Model Browser only lists design points. Design point sets and
                        design point methods are only visible from the Certification Browser. Design point set deletion from the
                            Certification Browser will result in referenced
                        design points (if design point does not exist in any other design point set)
                        and method deletion. Structural properties will not be
                affected.