/SENSOR/VEL

Block Format Keyword Describes the sensor activated when the velocity of the chosen node reaches the prescribed limit value.

Format

(1) (2) (3) (4) (5) (6) (7) (8) (9) (10)
/SENSOR/VEL/sens_ID/unit_ID
sens_title
Tdelay                
node_ID Vmax Fcut          

Definition

Field Contents SI Unit Example
sens_ID Sensor identifier.

(Integer, maximum 10 digits)

 
unit_ID Optional unit identifier.

(Integer, maximum 10 digits)

 
sens_title Sensor title.

(Character, maximum 100 characters)

 
Tdelay Time delay.

Default = 0.0 (Real)

[ s ]
node_ID Reference node identifier.

(Integer)

 
Vmax Max velocity.

(Real)

[ m s ] MathType@MTEF@5@5@+= feaagKart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVu0Je9sqqrpepC0xbbL8F4rqqrFfpeea0xe9Lq=Jc9 vqaqpepm0xbba9pwe9Q8fs0=yqaqpepae9pg0FirpepeKkFr0xfr=x fr=xb9adbaqaaeGaciGaaiaabeqaamaabaabaaGcbaWaamWaaeaada Wcaaqaaiaab2gaaeaacaqGZbaaaaGaay5waiaaw2faaaaa@39DE@
Fcut Filtering frequency of low pass filter for nodal velocity.

(Real)

[Hz]

Comments

  1. The sensor is activated when nodal velocity is greater than Vmax and after the time Tdelay.