/SENSOR/VEL
Block Format Keyword Describes the sensor activated when the velocity of the chosen node reaches the prescribed limit value.
Format
| (1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) | (9) | (10) |
|---|---|---|---|---|---|---|---|---|---|
| /SENSOR/VEL/sens_ID/unit_ID | |||||||||
| sens_title | |||||||||
| Tdelay | |||||||||
| node_ID | Vmax | Fcut | |||||||
Definition
| Field | Contents | SI Unit Example |
|---|---|---|
| sens_ID | Sensor
identifier. (Integer, maximum 10 digits) |
|
| unit_ID | Optional unit
identifier. (Integer, maximum 10 digits) |
|
| sens_title | Sensor
title. (Character, maximum 100 characters) |
|
| Tdelay | Time delay. Default = 0.0 (Real) |
|
| node_ID | Reference node
identifier. (Integer) |
|
| Vmax | Max velocity.
(Real) |
|
| Fcut | Filtering frequency of
low pass filter for nodal velocity. (Real) |
Comments
- The sensor is activated when nodal velocity is greater than Vmax and after the time Tdelay.