ReceivingAntennaData

Receiving antenna results generated by the Feko Solver.

Example

app = pf.GetApplication()
app:NewProject()
app:OpenFile(FEKO_HOME..[[/shared/Resources/Automation/MoM_PO_Misc_Example.fek]])

    -- Retrieve the 'ReceivingAntennaData' called 'FarFieldReceivingAntenna1'

rxAntennaData = app.Models[1].Configurations[1].ReceivingAntennas["FarFieldReceivingAntenna1"]

    -- Add the receiving antenna data to a Cartesian graph
    
graph = app.CartesianGraphs:Add()
receivingAntennaTrace1 = graph.Traces:Add(rxAntennaData)

Inheritance

The ReceivingAntennaData object is derived from the ResultData object.

The following objects are derived (specialisations) from the ReceivingAntennaData object:

Usage locations

The ReceivingAntennaData object can be accessed from the following locations:

Property List

Configuration
The result data's solution configuration in the model. (Read only SolutionConfiguration)
ContinuousFrequencyAxis
Continuous frequency axis exists. (Read only boolean)
DataSetAvailable
Valid result data exist. (Read only boolean)
Label
The object label. (Read/Write string)

Method List

GetDataSet ()
Returns a data set containing the power values. (Returns a DataSet object.)
GetDataSet (samplePoints number)
Returns a data set containing the power values. (Returns a DataSet object.)
GetDataSet (startFrequency number, endFrequency number, samplePoints number)
Returns a data set containing the power values. (Returns a DataSet object.)

Property Details

Configuration
The result data's solution configuration in the model.
Type
SolutionConfiguration
Access
Read only
ContinuousFrequencyAxis
Continuous frequency axis exists.
Type
boolean
Access
Read only
DataSetAvailable
Valid result data exist.
Type
boolean
Access
Read only
Label
The object label.
Type
string
Access
Read/Write

Method Details

GetDataSet ()
Returns a data set containing the power values.
Return
DataSet
The data set containing the power values.
GetDataSet (samplePoints number)
Returns a data set containing the power values.
Input Parameters
samplePoints(number)
The number of sample points used to sample the continuous frequency axis.
Return
DataSet
The data set containing the power values.
GetDataSet (startFrequency number, endFrequency number, samplePoints number)
Returns a data set containing the power values.
Input Parameters
startFrequency(number)
The start frequency used to sample the continuous frequency axis.
endFrequency(number)
The end frequency used to sample the continuous frequency axis.
samplePoints(number)
The number of sample points used to sample the continuous frequency axis.
Return
DataSet
The data set containing the power values.