SpiceProbeQuantity
The SPICE probe quantity properties.
Example
app = pf.GetApplication() app:NewProject() app:OpenFile(FEKO_HOME..[[/shared/Resources/Automation/SpiceProbeTest.fek]]) -- Add a cartesian graph. cartesianGraph = app.CartesianGraphs:Add() -- Add a SPICE probe trace. spiceProbesPlot = cartesianGraph.Traces:Add(app.Models[1].Configurations[1].SpiceProbes[1]) -- Adjust quantity properties of the plot. spiceProbesPlot.Quantity.ValuesNormalised = true spiceProbesPlot.Quantity.ValuesScaledToDB = true
Usage locations
The SpiceProbeQuantity object can be accessed from the following locations:
- Properties
- SpiceProbeTrace object has property Quantity.
Property List
- ComplexComponent
- The complex component of the value to plot, specified by the ComplexComponentEnum, e.g. Magnitude, Phase, Real, Imaginary. (Read/Write ComplexComponentEnum)
- PhaseUnwrapped
- Specifies whether the phase is unwrapped before plotting. This property is only valid when the ComplexComponent is Phase. (Read/Write boolean)
- Type
- The type of quantity to be plotted, specified by the SpiceProbeValueTypeEnum, e.g. Current or Voltage. (Read/Write SpiceProbeValueTypeEnum)
- ValuesNormalised
- Specifies whether the quantity values must be normalised to the range [0,1] before plotting. This property can be used together with dB scaling. This property is not valid when the ComplexComponent is Phase. (Read/Write boolean)
- ValuesScaledToDB
- Specifies whether the quantity values are scaled to dB before plotting. This property is only valid when the ComplexComponent is Magnitude. (Read/Write boolean)
Property Details
- ComplexComponent
- The complex component of the value to plot, specified by the ComplexComponentEnum, e.g. Magnitude, Phase, Real, Imaginary.
- Type
- ComplexComponentEnum
- Access
- Read/Write
- PhaseUnwrapped
- Specifies whether the phase is unwrapped before plotting. This property is only valid when the ComplexComponent is Phase.
- Type
- boolean
- Access
- Read/Write
- Type
- The type of quantity to be plotted, specified by the SpiceProbeValueTypeEnum, e.g. Current or Voltage.
- Type
- SpiceProbeValueTypeEnum
- Access
- Read/Write
- ValuesNormalised
- Specifies whether the quantity values must be normalised to the range [0,1] before plotting. This property can be used together with dB scaling. This property is not valid when the ComplexComponent is Phase.
- Type
- boolean
- Access
- Read/Write
- ValuesScaledToDB
- Specifies whether the quantity values are scaled to dB before plotting. This property is only valid when the ComplexComponent is Magnitude.
- Type
- boolean
- Access
- Read/Write