WOR - OUTLETREGIONS

WOR1

An extension type other than noext is requested for spherical outlet region #1. The extension is ignored.
Spherical outlet regions do not support extensions. In case an extension was required, other outlet region types must be used.

WOR2

Outlet region #1 does not have an active extension, but an extension outside of active interval is requested. Ignoring the inactive interval extensions.
When the outlet region's extension is set to "noext", all other extension related options are ignored. Disregard this warning if the extension is deliberately disabled. If an extension is required, please set "outletregion_exttyp" to "setacc" or "setvel".

WOR3

Outlet region #1 has an inactive extension, but an extension length is specified. Ignoring the extension.
When the outlet region's extension is set to "noext", all other extension related options are ignored. Disregard this warning if the extension is deliberately disabled. If an extension is required, please set "outletregion_exttyp" to "setacc" or "setvel".

WOR4

Oulet region #1 has an active extension, but no extension length is specified. Ignoring the extension.
The solver issues this warning when the extension length for an outlet region with an extension type "setacc" or "setvel" is missing. This may be due to typographical errors in the cfg or simply missing keywords "outletregion_extlen" or "outletregion_extlenodx". Since a zero length extension is effectively inactive and to save computational resources, the solver turns off the extension. Please provide an extension length if the outlet region requires an extension.

WOR5

Outlet region #1 has no specified start time. Assuming zero.
When no start time has been specified, outlet region uses a default value of simulation start.

WOR6

Sphere outlet region #1 has a radius smaller than dx.
An outlet region radius smaller than "dx" is not recommended. The behavior may be unpredictable.

WOR7

Cuboid outlet region #1 has at least one length value smaller than dx.
An outlet region side length smaller than "dx" is not recommended. The behavior may be unpredictable.

WOR8

Cylinder outlet region #1 has a radius smaller than dx.
An outlet region radius smaller than "dx" is not recommended. The behavior may be unpredictable.

WOR9

Cylinder outlet region #1 has a height smaller than dx.
An outlet region height smaller than "dx" is not recommended. The behavior may be unpredictable.

WOR10

The time-state series defined in S1 for outlet region #1 does not encompass the full duration of the simulation. Please make sure that time_start, time_end, tss_offset and tss_latch options are set according to your requirements.
The simulation will continue normally outside of the interval defined in time-state series file. The state value outside of the defined interval will depend on the "outletregion_tss_latch" option. This warning may be safely ignored if this is desired behavior.

WOR11

Ramp up and ramp down times for outlet region #1 are ignored.
An outlet region will ignore ramp up and ramp down times, if specified, when using a time-state series file. The simulation will otherwise continue normally.