WSE - SURFEXTS
WSE1
The non-synchronized output time interval specified in "extractor_dtoutput" for extractor S1 is less than simulation time step size.
This warning is displayed when a non-synchronized output time interval "extractor_dtoutput" shorter than simulation time step size is requested for an "extractor". It is recommended to set extractor "extractor_dtoutput" to a value between "dt_output" and "dt_phaseinfo".
WSE2
The number of samples requested for S1 in "extractor_nsample" must be a non-negative integer.
This warning is displayed when the number of samples specified in "extractor_nsample" is less than 1 or a non-integer value.