Use the Defaults tool to define global surface conditions for thermal radiation.
If conditions
are set using the other Thermal Radiation Surfaces tools,
the parameters defined in this tool will be overridden.
-
From the Radiation ribbon, click the arrow next to the
Thermal Radiation Surfaces tool set, then
select Defaults.
The Default Radiation Boundary dialog
opens.
-
Click the Radiation condition tab from the Settings
menu. Define values for the default radiation boundary settings.
-
Click the Output controls tab. Define the output
frequency and/or output time interval at which results are extracted.
-
Click the Agglomeration tab. Activate the check box, if
desired, and input agglomeration values.