Batch Mode

Run Model Verification operations in batch mode.

Batch Command

Batch command to load all the functionalities of Model Verification into the batch mode of HyperWorks.

<altair_home>/hm/bin/<platform>/hmbatch.exe –tcl <mvd/src\main>/batch.tcl

Batch Options

Syntax and the description of the available options when using Model Verification in batch mode.

Intersection Check

Supported Batch options for Intersection checks.

Mandatory Arguments

"%hmbatch%"
File path of hmbatch.exe
Value: hmbatch.exe
-tcl
File path of batch.tcl
Value: batch.tcl
-mvd-feature
Function name
Value: intersection
-mvd-input
Folder/File name
Value: "%input%"
-mvd-input-type
Cad/Fe/XML file type of %input%
Value: " iges"
-mvd-output
Result .xml file name
Value: "intresult.xml"
-mvd-report
Report output path
Value: "%report%"

Optional Arguments

-nocommand
No input needed
Value: Blank
-nouserprofiledialog
No input needed
Value: Blank
-mvd-action
Action type
Value: check/report/both
-mvd-bg
No input needed
Value: Blank
-mvd-ncpu
# of cores in current machine
Value: 2
-mvd-log
File name/File name
Value: mvdLog.log
-mvd-project-name
Any string value display in report
Value: “Name”
-mvd-slide-number
Any integer value display in report
Value: “1”
-mvd-progress
File name/File name
Value: mvdprogress.log

Example

Example of a batch command.
"%hmbatch%" -nocommand -nouserprofiledialog -tcl "%tcl_file%" -mvd-feature intersection 
-mvd-input "%input%" -mvd-input-type "iges" -mvd-output "%output%" -mvd-report "%report%" 
-mvd-action both -mvd-report-scope both -mvd-bg -mvd-ncpu 1 -mvd-log mvdLog.log -mvd-progress 
mvdprogress.log

Comparison Check

Supported Batch options for Comparison checks.

Mandatory Arguments

"%hmbatch%"
File path of hmbatch.exe
Value: hmbatch.exe
-tcl
File path of batch.tcl
Value: batch.tcl
-mvd-feature
Function Name
Value: intersection
-mvd-base
Folder path/File name
Value: "%base%"
-mvd-base-type
Cad/Fe/XML file type of %input%
Value: “iges”
-mvd-variant
Folder path/File name
Value: "%variant%"
-mvd-variant-type
Cad/Fe/XML file type of %input%
Value: “radioss”
-mvd-output
Result .xml file name
Value: "compresult.xml"
-mvd-report
Report output path
Value: "%report%"

Optional Arguments

-nocommand
No input needed
Value: Blank
-nouserprofiledialog
No input needed
Value: Blank
-mvd-action
Action type
Value: check/report/both
-mvd-report-scope
Report Option
Value: Excel/PPT/both
-mvd-bg
No input needed
Value: Blank
-mvd-ncpu
# of cores in current machine
Value: 2
-mvd-log
File name/File name
Value: mvdLog.log
-mvd-progress
File name/File name
Value: mvdprogress.log

Example

Example of a batch command.
"%hmbatch%" -nocommand -nouserprofiledialog -tcl "%tcl_file%" 
-mvd-feature comparison -mvd-base "%base%" -mvd-base-type iges -mvd-variant 
"%variant%" -mvd-variant-type dyna -mvd-output "%output%" -mvd-report "%report%" 
-mvd-action both -mvd-report-scope both -mvd-bg -mvd-ncpu 1 -mvd-log mvdLog.log 
-mvd-progress mvdprogress.log

Spotweld Check (Fe)

Supported Batch options for Spotweld checks (Fe).

Mandatory Arguments

"%hmbatch%"
File path of hmbatch.exe
Value: hmbatch.exe
-tcl
File path batch.tcl
Value: batch.tcl
-mvd-feature
Function name
Value: spotweld
-mvd-input
Folder path of spot file & Fe file
Value: "%input%"
-mvd-input-type
Fe file type of %input%
Value: "optistruct/radioss/pam"
-mvd-output
Report output path
Value: "%output%"
Note: The Spot file type is read from the configuration file.

Optional Arguments

-nocommand
No input needed
Value: Blank
-nouserprofiledialog
No input needed
Value: Blank
-mvd-action
Action needed
Value: check/report/both
-mvd-bg
No input needed
Value: Blank
-mvd-ncpu
# of cores in current machine
Value: 2
-mvd-log
File name / File name
Value: mvdLog.log
-mvd-project-name
Any string value display in report
Value: “Name”
-mvd-slide-number
Any integer value display in report
Value: “1”
-mvd-progress
File name / File name
Value: mvdprogress.log

Example

Example of a batch command.
"%hmbatch%" -nocommand -nouserprofiledialog -tcl "%tcl_file%" 
-mvd-feature spotweld -mvd-input "%input%" -mvd-input-type “pam” -mvd-output 
"%output%" -mvd-action both -mvd-report-scope both -mvd-bg -mvd-ncpu 1 -mvd-log 
mvdLog.log -mvd-progress mvdprogress.log

Spotweld Check (CAD)

Supported Batch options for Spotweld checks (CAD).

Mandatory Arguments

"%hmbatch%"
File path of hmbatch.exe
Value: hmbatch.exe
-tcl
File path batch.tcl
Value: batch.tcl
-mvd-feature
Function name
Value: spotweld
-mvd-input
Folder path contains spot file
Value: "%input%"
-mvd-spotweld-bom
.xml file path
Value: "%bomfile%"
-mvd-output
Report output path
Value: "%output%"
Note: The Spot file type is read from the configuration file.

Optional Arguments

-nocommand
No input needed
Value: Blank
-nouserprofiledialog
No input needed
Value: Blank
-mvd-action
Action type
Value: check/report/both
-mvd-bg
No input needed
Value: Blank
-mvd-ncpu
# of cores in current machine
Value: 2
-mvd-log
File name/File name
Value: mvdLog.log
-mvd-project-name
Any string value display in report
Value: "Name"
-mvd-slide-number
Any integer value display in report
Value: “1”
-mvd-progress
File name/File name
Value: mvdprogress.log

Example

Example of a batch command.
"%hmbatch%" -nocommand -nouserprofiledialog -tcl "%tcl_file%" 
-mvd-feature spotweld -mvd-input "%input%" -mvd-spotweld-bom "%bomfile%" 
-mvd-output "%output%" -mvd-action both -mvd-report-scope both -mvd-bg 
-mvd-ncpu 1 -mvd-log mvdLog.log -mvd-progress mvdprogress.log

Connection Check (CAD)

Supported Batch options for Connection checks (CAD).

Mandatory Arguments

"%hmbatch%"
File path of hmbatch.exe
Value: hmbatch.exe
-tcl
File path batch.tcl
Value: batch.tcl
-mvd-feature
Function Name
Value: connection
-mvd-input
Folder path
Value: "%input%"
-mvd-connection-bom
.xml file path
Value: "%bomfile%"
-mvd-output
Report output path
Value: "%output%"

Optional Arguments

-nocommand
No input needed
Value: Blank
-nouserprofiledialog
No input needed
Value: Blank
-mvd-action
Action type
Value: check/report/both
-mvd-bg
No input needed
Value: Blank
-mvd-ncpu
# of cores in current machine
Value: 2
-mvd-log
File name/File name
Value: mvdLog.log
-mvd-project-name
Any string value display in report
Value: “Name”
-mvd-slide-number
Any integer value display in report
Value: “1”
-mvd-progress
File name/File name
Value: mvdprogress.log

Example

Example of a batch command.
"%hmbatch%" -nocommand -nouserprofiledialog -tcl "%tcl_file%" 
-mvd-feature connection -mvd-input "%input%" -mvd-connection-bom "%bomfile%" 
-mvd-output "%output%" -mvd-action both -mvd-report-scope both -mvd-bg -mvd-ncpu 
1 -mvd-log mvdLog.log -mvd-progress mvdprogress.log

Free-Part Check (CAD)

Supported Batch options for Free-Part checks (CAD).

Mandatory Arguments

"%hmbatch%"
File path of hmbatch.exe
Value: hmbatch.exe
-tcl
File path batch.tcl
Value: batch.tcl
-mvd-feature
Function name
Value: freepart
-mvd-input
Folder path (contains Spot file)
Value: "%input%"
-mvd- freepart-bom
XML file path
Value: "%bomfile%"
-mvd-output
Report output path
Value: "%output%"
Note: The Spot file type is read from the configuration file.

Optional Arguments

-nocommand
No input needed
Value: Blank
-nouserprofiledialog
No input needed
Value: Blank
-mvd-action
Action type
Value: check/report/both
-mvd-bg
No input needed
Value: Blank
-mvd-ncpu
# of cores in current machine
Value: 2
-mvd-log
File name / File name
Value: mvdLog.log
-mvd-project-name
Any string value display in report
Value: “Name”
-mvd-slide-number
Any integer value display in report
Value: “1”
-mvd-progress
File name / File name
Value: mvdprogress.log

Example

Example of a batch command.
"%hmbatch%" -nocommand -nouserprofiledialog -tcl "%tcl_file%" 
-mvd-feature freepart -mvd-input "%input%" -mvd-output "%output%" -mvd-freepart-bom 
"%bomfile%" -mvd-action both -mvd-report-scope both -mvd-bg -mvd-ncpu 1 -mvd-log 
mvdLog.log -mvd-progress mvdprogress.log

Spot Comparison Check

Supported Batch options for Spot Comparison checks.

Mandatory Arguments

"%hmbatch%"
File path of hmbatch.exe
Value: hmbatch.exe
-tcl
File path batch.tcl
Value: batch.tcl
-mvd-feature
Function name
Value: spotweld-comparison
-mvd-base
File path of spot file A
Value: "%base%"
-mvd-variant
File path of spot file B
Value: "%variant%"
-mvd-spotcompare-bom
.xml file path
Value: "%bomfile%"
-mvd-report
Report output path
Value: "%report%"
Note: The Spot file type is read from the configuration file.

Optional Arguments

-nocommand
No input needed
Value: Blank
-nouserprofiledialog
No input needed
Value: Blank
-mvd-action
Action type
Value: check/report/both
-mvd-bg
No input needed
Value: Blank
-mvd-ncpu
# of cores in current machine
Value: 2
-mvd-log
File name/File name
Value: mvdLog.log
-mvd-project-name
Any string value display in report
Value: “Name”
-mvd-slide-number
Any integer value display in report
Value: “1”
-mvd-progress
File name/File name
Value: mvdprogress.log

Example

Example of a batch command.
"%hmbatch%" -nocommand -nouserprofiledialog -tcl "%tcl_file%" 
-mvd-feature spotweld-comparison -mvd-base "%base%" -mvd-variant "%variant%" 
-mvd-spotcompare-bom "%bom%" -mvd-report "%report%" -mvd-action both 
-mvd-report-scope both -mvd-bg -mvd-ncpu 1 -mvd-log mvdLog.log -mvd-progress mvdprogress.log

Batch Mode Error Codes

Error messages displayed when you use incorrect input argument.

SL Error Code Function and Message
1 1001 Import: Missing CAD file to XML converter
2 1002 Import: Failed to import CAD
3 1003 Import: Failed to export the FE part to the file
4 1004 Import: Problem obtaining HyperMesh version
5 1005 Import: Unable to find the result file
6 1006 Import: Unable to find the XML file
7 1007 Import: Failed to export the FE part to the file
8 1008 Import: Unable to find the result file in Import BG
9 1009 Import: Select only one module.
10 1010 Import: Invalid directory name specified
12 2001 Offset: Failed in license checkout for Offset
13 2002 Offset: Unknown action type in Offset
14 2003 Offset: Failed to export the FE part to the file in Offset
15 2004 Offset: No valid modules selected
17 3001 Comparison: Unable to find the result file in BG
18 3002 Comparison: No valid modules selected
19 3003 Comparison: Select two or more modules for reporting
20 3004 Comparison: No files in module selected. Import the modules for comparison.
21 3005 Comparison: Unable to compare two modules in parental relationship
22 3006 Comparison: Children found for Selected Module - Import cannot be done. For Compare Check - Select two or more modules
23 3007 Comparison Report: No template file specified in the configuration for excel
24 3008 Comparison Report: No template worksheet specified in the configuration for excel
25 3009 Comparison Report: Template file not found in Comparison for excel
26 3010 Comparison Report: Worksheet not found in the template for excel
27 3011 Comparison Report: Failed in license checkout
28 3012 Comparison Report: Record/Result file not found
29 3013 Comparison Report: No template row specified in the configuration
30 3014 Comparison Report: Invalid variant index
31 3015 Comparison Report: Problem obtaining HyperMesh version
32 3016 Comparison Report: No template file specified in the configuration for PPT
33 3017 Comparison Report: No layout specified in the configuration for PPT
34 3018 Comparison Report: Template file not found in PPT
36 4001 Intersection: Failed in license checkout
37 4002 Intersection: No valid modules selected in Intersection
38 4003 Intersection Report: No template file specified in the configuration for PPT
39 4004 Intersection Report: No layout specified in the configuration for PPT
40 4005 Intersection Report: Template file not found in PPT
42 5001 Spotweld: Failed in license checkout
43 5002 Spotweld: Unable to find connector files
44 5003 Spotweld: Unable to load FE model files
45 5004 Spotweld: Unable to import model, Check Configuration
46 5005 Spotweld: Unable to merge the hm file in HyperMesh
47 5006 Spotweld: Unable to load result file
48 5007 Spotweld: Unable to load model file
49 5008 Spotweld: Unexpected action type
50 5009 Spotweld: No connector files found in the input path
51 5009 Spotweld: No valid modules selected
52 5010 Spotweld Report: Error in sphere creation
53 5011 Spotweld Report: Result Model not saved successfully. Backup in output path
54 5012 Spotweld Report: No template file specified in the configuration for PPT
55 5013 Spotweld Report: No layout specified in the configuration for PPT
56 5014 Spotweld Report: Template file not found in PPT
58 6001 Connection: Failed in license checkout
59 6002 Connection: Unable to calculate the centroid from surfaces of component
60 6003 Connection: Unable to create lines between centroid and surfaces of component
61 6004 Connection: Unable to calculate the center line direction from surface edges of component
62 6005 Connection: Unable to find the appropriate line to determine the center line direction
63 6006 Connection: Unable to read the boltnut.hm file in HyperMesh
64 6007 Connection: Unable to find the result file in BG
65 6008 Connection: Unable to load result file
66 6009 Connection: Unable to load model file
67 6010 Connection Unexpected action type
68 6010 Connection Report: Check Result does not exist
69 6011 Connection Report: No template file specified in the configuration for PPT
70 6012 Connection Report: No layout specified in the configuration for PPT
71 6013 Connection Report: Template file not found in PPT
73 7001 Freepart: Failed in license checkout
74 7002 Freepart: Unable to load FE model files
75 7003 Freepart: Unable to read the freepartmodel.hm file in HyperMesh
76 7004 Freepart: No Model loaded
77 7005 Freepart: Unable to find the result file in BG
78 7006 Freepart: Unable to find connector files
79 7007 Freepart: Unexpected action type
80 7008 Freepart: Unable to load result file
81 7008 Freepart: Unable to load model file
82 7009 Freepart: No connector files found in the input path
83 7010 Freepart Report: No template file specified in the configuration for PPT
84 7011 Freepart Report: No layout specified in the configuration for PPT
85 7012 Freepart Report: Template file not found in PPT

Batch File Example

Example of a Model Verification batch file.

Note:
You must edit “ALTAIR_HOME”, “datapath” path in the following example.
set ALTAIR_HOME=C:\Program Files\Altair\2019
set dataPath=G:\BVT\2019\data
set hmbatch=%ALTAIR_HOME%\hm\bin\win64\hmbatch.exe
set tcl_file=%ALTAIR_HOME%\hm\scripts\MVD\mvdMain\src\main\batch.tcl
set base=%dataPath%\batch\iges
set variant=%dataPath%\batch\dyna
set output=%dataPath%\comparisonres.xml
set report=%dataPath%

cd /d g:
cd %dataPath%
IF not exist %report% (mkdir %report%)

"%hmbatch%" -nocommand -nouserprofiledialog -tcl "%tcl_file%" -mvd-feature comparison -mvd-base "%base%" -mvd-base-type iges -mvd-variant "%variant%" -mvd-variant-type dyna -mvd-output "%output%" -mvd-report "%report%" -mvd-action both -mvd-report-scope both -mvd-bg -mvd-ncpu 1 -mvd-log mvdLog.log -mvd-progress mvdprogress.log