/DT/FVMBAG/Iflag
Engine Keyword Time step for control for Finite Volume Method airbag.
Format
/DT/FVMBAG/Iflag
Definitions
| Field | Contents | SI Unit Example |
|---|---|---|
| Iflag | Finite volumn merge flag.
|
|
| Scale factor on time step. | ||
| Minimum time step. |
Comments
- The and can be defined to insure stability and a minimum time step size by triggering additional finite volume merges when the FVMBAG entity penalizes the computation.