Restart for Fatigue Analysis
Restart for fatigue analysis is available from linear static analysis results, local model results, and random response results.
Fatigue Restart from Linear Static Analysis Results
ASSIGN,H3DRES,10,linear_static.h3d
SUBCASE 1
ANALYSIS=STATIC
IMPORT(SUB=1)=10
SUBCASE 21
FATDEF = 100
FATPARM = 252
FATSEQ = 401
BEGIN BULK
FATSEQ,401
+,501,1
FATEVNT,501,601
FATLOAD,601,701,1,1.000,5.00,0.0
Fatigue Restart from Local Model Results
(Imported global model .h3d-submodeling)
ASSIGN,H3DRES,10,global.h3d
SUBCASE 1
SPC=11
IMPORT(SUB=1)=10
SUBCASE 21
FATDEF = 100
FATPARM = 252
FATSEQ = 401
BEGIN BULK
FATSEQ,401
+,501,1
FATEVNT,501,601
FATLOAD,601,701,1,1.000,5.00,0.0
SPC,11,1,123,M
+,GSET
SPC,11,2,123,M
+,GSET
Fatigue Restart from Random Response Results
(Restarted from .h3d coming from FRF analysis results)
ASSIGN,H3DRES,10,frf.h3d
SUBCASE 1
ANALYSIS=MFREQ
IMPORT(SUB=1)=10
SUBCASE 2
ANALYSIS=RANDOM
RANDOM = 100
SUBCASE 9
LABEL fatigue
ANALYSIS FATIGUE
FATDEF = 13
FATPARM = 15
FATSEQ = 23
Begin bulk
FATSEQ,23
+,24,1
FATEVNT,24,22
FATLOAD,22,,2