A non-uniform pressure is assumed inside the volume. The gas flow in
FVMBAG1 is solved using a finite volume integration scheme which
allows the gas flow through the airbag to be correctly modeled.
Since the gas flow simulated, the unfolding and deployments behavior is correct which
is needed for out of position occupant simulations and curtain airbag
deployments.
Perfect gas law and adiabatic conditions are assumed. Injected mass, velocity and
temperature are defined as a time function. The injected velocity is obtained
using:
(1)
Where, S is the injector surface.
A sensor may define the inflator starting time.
Deflation of vent hole is available after reaching a pressure
(Pdef) or time
(tdef) criteria.
In this version, heat gas capacity
Cp is assumed constant.
More further detail, refer to FVMBAG1 Airbag Modeling Guidelines.