Free Size Panel
Use the Free Size panel to define design domains for free size optimization.
Create Subpanel
| Option | Action | 
|---|---|
| desvar | Specify a name for the design variable. | 
| type | Select an entity type. | 
| props | Select a property. | 
| minimum thickness | Specify a non-zero value for the minimum shell (for PSHELL) or set global TMINPLY for PCOMP and PCOMPG. | 
| maximum thickness | Specify a maximum thickness other than the shell (for PSHELL) or set global TMINPLY for PCOMP and PCOMPG thickness defined on the property card. | 
Update Subpanel
| Option | Action | 
|---|---|
| desvar | Specify a name for the design variable. | 
| type | Select an entity type. | 
| props | Select a property. | 
| minimum thickness | Specify the minimum thickness or select zero to be the minimum. | 
| maximum thickness | Choose to use the thickness value from the selected property, or enter a thickness value. | 
Parameters Subpanel
| Option | Action | 
|---|---|
| desvar | Specify a name for the design variable. | 
| minmemb off / mindim = | Specify a value for the member size control, or toggle the switch to off. | 
| stress constraint | Specify a value for the stress constraint, or toggle the switch to none. | 
| fatigue constraint | Specify a value for the fatigue constraint, or toggle the switch to none. | 
Composites Subpanel
| Option | Action | 
|---|---|
| desvar | Select the DSIZE design variable. | 
| laminate thickness: min thickness /off | Specify a value for the laminate thickness (LAMTHK) minimum, or toggle the switch off. | 
| laminate thickness: max thickness /off | Specify a value for the laminate thickness (LAMTHK) maximum, or toggle the switch off. | 
| ply thickness: no. of constraints | Display the number of constraints for ply thickness (PLYTHK). To modify this number, click Edit. | 
| ply percentage: no. of constraints | Display the number of constraints for ply thickness percentage (PLYPCT). To modify this number, click Edit. | 
| ply manufacture: no. of constraints | Display the number of constraints for manufacturable ply thickness (PLYMAN). To modify this number, click Edit. | 
| balance: no. of constraints | Display the number of constraints for balancing (BALANCE). To modify this number, click Edit. | 
| constant: no. of constraints | Display the number of constraints for constant thickness (CONST). To modify this number, click Edit. | 
| ply drop-off: no. of constraints | Display the number of constraints for ply drop-off (PLYDRP). To modify this number, click Edit. | 
Pattern Grouping Subpanel
| Option | Action | 
|---|---|
| desvar | Specify a name for the design variable. | 
| pattern type | Select the pattern type. | 
| second node | Used for 2-plns sym or 3-plns sym types. | 
| ucyc | Specify the number of repetitions in 360 degrees. Used for cyclic or cyc 1-pln types. | 
Pattern Repetition Subpanel
| Option | Action | 
|---|---|
| desvar | Specify a name for the design variable. | 
| main / secondary / none | Choose whether to establish a main coordinate system, a secondary design variable, or neither. | 
| system /coordinates | Choose to manually enter the values for the coordinate system, or to graphically select the system. | 
| global system / local system | Reference coordinate system. | 
| anchor | Select the anchor node. | 
| sx /sy /sz | Specify x, y and z scale factors. | 
Zone Based Subpanel
| Option | Action | 
|---|---|
| desvar | Select the DSIZE design variable. | 
| zone definition sets | Select sets for zone based (GROUP) free-sizing optimization. | 
Command Buttons
| Button | Action | 
|---|---|
| create | Create the design variable. | 
| edit | Open the property collector panel to edit the property. | 
| reject | Revert the most recent changes. | 
| review | Review the load in the graphic area. | 
| update | Update the load with the most recent changes. | 
| return | Exit the panel. |