Normal Mode Extraction
- Select Subcase
- Select the required method
- EIGRA - Defines the data required to perform real eigenvalue analysis with the Automated Multi-Level Sub-structuring technique.
- EIGRL - Defines data required to perform real eigenvalue analysis (vibration or buckling) with the Lanczos Method.
- Define the values for
- Minimum frequency
- Maximum frequency, or
- Number of ModesNote: Value fields contain default values. You can use the same or you can modify according to the needs.
- Add normal mode extraction load collector
- Update an existing normal mode load collector
- Refer panel data
- Delete Selected and Delete All from the list