*CE_ConnectorSpotTrim
Trims/splits spot line connectors using nodes.
Syntax
*CE_ConnectorSpotTrim mark_id node_mark_id tolerance snap mode
Type
HyperMesh Tcl Modify Command
Description
Trims/splits spot line connectors using nodes.
Inputs
- mark_id
 - The ID of the mark of connectors. Valid values are 1 and 2.
 - node_mark_id
 - The ID of the mark of nodes. Valid values are 1 and 2.
 - tolerance
 - The tolerance value used to snap the nodes to the point of spot connectors when snap is 1.
 - snap
 - 0 - Do not snap nodes to spot connectors
 - mode
 - 0 - Split
 
Examples
To split spot connector 101 using node 1001:
*createmark connectors 1 101
*createmark nodes 1 1001
*CE_ConnectorSpotTrim 1 1 0.5 1 0
    Errors
if { [ catch {command_name...} ] } {
   # Handle error
}Version History
2021