Absorbs certain FE information into connectors.
    Syntax
      
      *CE_FE_Absorb
        create_flag curr_solver num_body_cfgs body_cfgs num_head_cfgs head_cfgs elem_filter
          elem_filter_size string_array number_of_strings
    
    Type
      
      HyperMesh Tcl Modify Command
    
    Description
      
      Absorbs certain FE information into connectors.
    
    Inputs
      
      
        
          - create_flag
 
          - 0 - Spot connectors 
 
          - 1 - Seam/area connectors
 
        
        
          - curr_solver
 
          - The current solver name.
 
        
        
          - num_body_cfgs
 
          - The size of the connector body configuration list.
 
        
        
          - body_cfgs
 
          - The connector body configuration list. Must be enclosed in quotes.
 
        
        
          - num_head_cfgs
 
          - The size of the connector head configuration list.
 
        
        
          - head_cfgs
 
          - The connector head configuration list. Must be enclosed in quotes.
 
        
        
          - elem_filter
 
          - A flag indicating whether to use the displayed or selected elements:0 - Displayed
            elements 
 
          - 1 - Selected elements. An integer array containing the element IDs must be created
            using the *createarray command.
 
        
        
          - elem_filter_size
 
          - Integer indicating the size (number of elements) in the elem_filter
            array created using *createarray.
 
        
        
          - string_array
 
          - A string array containing optional details for absorb. 
 
          - Spot connectors:
              
                - check_for_material=<value>
 
                - 0 - Do not check for material for mat100 (hexa)
 
                - 1 - Check for material for mat100 (hexa)
 
              
              
                - combine=<value>
 
                - 0 - Do not combine in case of equivalent body nodes
 
                - 1 - Combine in case of equivalent body nodes
 
              
              
                - conn_at_centernode=<value>
 
                - 0 - Do not enable Connector at Centernode for rbe3 (load transfer)
 
                - 1 - Enable Connector at Centernode for rbe3 (load transfer)
 
              
              
                - force_proj=<value>
 
                - 0 - Do not enable ACM pattern recognition
 
                - 1 - Enable ACM pattern recognition
 
              
              
                - link_by_card=<value>
 
                - 0 - Do not find link entities by card
 
                - 1 - Find link entities by card
 
              
              
                - link_by_interface=<value>
 
                - 0 - Do not find link entities by interface
 
                - 1 - Find link entities by interface
 
              
              
                - mcf=<file>
 
                - The file name for the main connection file.
 
              
              
                - org=<value>
 
                - 0 - Use current component 
 
                - 1 - Move connectors to FE component
 
              
              
                - rul=<rule>
 
                - The re-connect rule "None", "User id" or "User name".
 
              
              
                - shell_connect=<type>
 
                - "body", "head", "projs", or "none".
 
              
              
                - t_connect=<type>
 
                - "body", "head", "projs", or "none".
 
              
              
                - thickness_type=<type>
 
                - The spot connector thickness type:
 
                - 1 - equival (T1+T2)/2 
 
                - 3 - shell gap 
 
                - 5 - const thickness
 
              
              
                - tol=<value>
 
                - The maximum distance allowed between the connector and each of its links.
 
              
              
                - type2_interface=<value>
 
                - 0 - Do not find link entities by interface for type2 (spring)
 
                - 1 - Find link entities by interface for type2 (spring)
 
              
              
                - weld_cfg_name=<name>
 
                - The type of FE realization that needs to be converted to connectors.
 
              
              
                - weld_type_num=<id>
 
                - The selected weld type ID.
 
              
              
                - weld_type_name=<name>
 
                - The selected weld type name.
 
              
            
 
          - Seam/area connectors:
              
                - area_absorption=<value>
 
                - 0 - Do not absorb as area 
 
                - 1 - Absorb as area if possible
 
              
              
                - area_headonly=<value>
 
                - 0 - Do not only absorb FE with heads as area 
 
                - 1 - Only absorb FE with heads as area
 
              
              
                - area_in_middle=<value>
 
                - 0 - Do not move area to the middle position 
 
                - 1 - Move area to the middle position
 
              
              
                - cluster_identify=<value>
 
                - 0 - Do not absorb single element cluster as area 
 
                - 1 - Absorb single element cluster as area
 
              
              
                - group_links=<value>
 
                - 0 - Do not organize the links into two groups 
 
                - 1 - Organize the links into two groups
 
              
              
                - mcf=<file>
 
                - The file name for the main connection file.
 
              
              
                - org=<value>
 
                - 0 - Use current component 
 
                - 1 - Move connectors to FE component
 
              
              
                - rul=<rule>
 
                - The re-connect rule "None", "User id" or "User name".
 
              
              
                - seam_absorption=<value>
 
                - 0 - Do not absorb as seam 
 
                - 1 - Absorb as seam if possible
 
              
              
                - seam_headonly=<value>
 
                - 0 - Do not only absorb FE with heads as seam 
 
                - 1 - Only absorb FE with heads as seam
 
              
              
                - select_special=<value>
 
                - 0 - Do not enable enhanced approach 
 
                - 1 - Enable enhanced approach
 
              
              
                - tie_contact=<value>
 
                - 0 - Do not enable With tie contact 
 
                - 1 - Enable With tie contact
 
              
              
                - tol=<value>
 
                - The maximum distance allowed between the connector and each of its links.
 
              
            
 
        
        
          - number_of_strings
 
          - The size of the options string array.
 
        
      
    
    Examples
      
      Absorb spot connectors:
      *createarray 1 0
*createstringarray 10 "weld_type_num=74" "weld_type_name=acm (general) " "weld_cfg_name=custom" "shell_connect=head" "t_connect=body" "mcf=" "org=0" "rul=None" "tol=20.0" "thickness_type=1"
*CE_FE_Absorb 0 "nastran" 1 "208" 1 "56" 1 1 1 10
      Absorb seam connectors:
      *createarray 1 0
*createstringarray 11 "seam_absorption=1" " seam_headonly=1" "area_absorption=0" "area_headonly=0"  "area_in_middle=1" "cluster_identify=0" "mcf=" "org=0" "rul=None" "tol=20.0" "group_links=0"
*CE_FE_Absorb 1 "nastran" 2 "208 206" 0 "" 1 1 1 11
    
    Errors
      
      Incorrect usage results in a 
Tcl error. To detect
        errors, you can use the 
catch
        command:
if { [ catch {command_name...} ] } {
   # Handle error
}