*CE_ConnectorCreateByMarkAndRealizeWithDetails
Create a certain style of connectors at locations specified by mark using certain rules and details, and realize them using specified details.
Syntax
*CE_ConnectorCreateByMarkAndRealizeWithDetails entitytype entitymark ce_style num_ents linkentity linkentmark solvername config fe_type tolerance options options_size
Type
HyperMesh Tcl Modify Command
Description
Create a certain style of connectors at locations specified by mark using certain rules and details, and realize them using specified details.
Inputs
- entitytype
 - The type of specified location(s). Possible options depend on the type of connector:
- points
 - Valid for Spot, Bolt, and Apply Mass connectors.
 - nodes
 - Valid for Spot, Bolt, and Apply Mass connectors.
 - lines
 - Valid for Spot, Bolt, and Seam connectors.
 - elems
 - Valid only for Area connectors.
 - surfs
 - Valid only for Area connectors.
 
 - entitymark
 - Mark containing the list of points, nodes, lines, elems, or surfs.
 - ce_style
 - Style of connectors. Valid options are:
- spot
 - bolt
 - apply_mass
 - seam
 - area
 
 - num_ents
 - Number of links.
 - linkentity
 - Type of link entity:
- elems
 - Valid for Spot or Apply_mass connectors.
 
- nodes
 - Valid for Spot or Apply_mass connectors.
 
- comps
 - Valid for Spot, Bolt, Apply_mass, Seam, or Area connectors.
 
- surfs
 - Valid for Spot, Seam, or Area connectors.
 
- tags
 - Valid for Spot or Apply_Mass connectors.
 
 - linkentmark
 - The mark containing the link entities.
 - solvername
 - The target solver for realization.
 - config
 - The element type for realization:
- 2 - plot
 - 3 - weld
 - 5 - rigid
 - 21 - spring
 - 55 - rigidlink
 - 60 - bar2
 - 61 - rod
 - 70 - gap
 - 104 - quads
 - 1001 - custom
 
 - fe_type
 - The type ID for the current solver specified in the FEconfig file. Only used for custom config (1001).
 - tolerance
 - The maximum distance allowed between the connector (on mark) and each of its links during realization.
 - options
 - The string array to specify optional details for creation:
Detail Description Default Value area_mesh_type Mesh type for area connectors when using SURFS as the location: - 0 = Trias
 - 1 = Quads
 - 2 = Mixed
 - 3 = Right trias
 
1 area_mesh_size Mesh size for area connectors when using SURFS as the location. 10.0 link_elems_geom Connecting element (elems) or geometry (geom). elems link_rule Link rule: - now
 - at_fe_realize
 - none
 
none relink_rule Relink rule: - id
 - name
 - none
 
none tol_flag Indicates whether to use tolerance. - 0 = Yes
 - 1 = No
 
0 tol Add entities as links only within this distance of the specified location. 0.0 line_spacing Spacing for spot or seam connectors on lines. 1.0 line_density Density for spot or seam connectors on lines. 0 line_offset_flag Indicates whether to offset connector. - 0 = Yes
 - 1 = No
 
0 line_offset Offset value from the ends of line for spot or seam connectors. 0.0 seam_area_group Group flag for seam or area connector. - 0 = No
 - 1 = Yes
 
0 area_width Width of area connectors created from node lists or line lists. 1.0 area_offset Offset area connnector(s) created from node or line lists from the selected location by this value. 0.0 ce_propertyid Property ID value. 0 ce_systems Build system flag. - 0 = No
 - 1 = Yes
 
0 ce_connectivity Connectivity type: - 0 - Mesh independent
 - 1 - Mesh dependent + remesh
 - 2 - Mesh dependent + ensure projection
 - 3 - Mesh dependent + quad transition
 - 4 - Mesh dependent + projection and find nodes
 - 5 - Mesh dependent + find nearest nodes
 
0 ce_forcecollinear Collinear flag: - 0 = Non-collinear
 - 1 = Collinear
 
0 ce_nonnormal Non-normal projection flag. - 0 = Normal
 - 1 = Non-normal
 
0 ce_diameter Diameter value for some custom types (acm, cweld, mat100, etc.) 0 ce_areathicknesstype Thickness type for area connector: - 0 = (T1+T2)/2
 - 1 = Shell gap
 - 2 = Mid thickness
 - 3 = Const thickness
 
0 ce_areaconstthickness Constant thickness value for area connector. 0.0 ce_areastacksize Density for area connector. 0 ce_boltmindiameter Minimum diameter for a hole to be accepted as a bolt hole. 0.0 ce_boltmaxdiameter Maximum diameter for a hole to be accepted as a bolt hole. 10.0 ce_appliedmass Mass value for apply massx 0.0 ce_appliedmassdis Mass distribution type for apply mass: - 0 = Apply to all nodes.
 - 1 = Divide by nodes.
 - 2 = Divide by area.
 - 3 = Unit area.
 
0 ce_configfile fe configuration file. "" ce_dvstfile Diameter vs. thickness file. "" ce_propertyscript Property script file. "" ce_fevectorrevers Reverse direction flag for seam connectors: - 0 = No reverse
 - 1 = Reverse
 
0  - options_ size
 - The size of the options string array.
 
Examples
*createmark nodes 1 10
*createmark components 2 3 4
*createstringarray 8 "link_elems_geom=elems" "link_rule=now" "relink_rule=none" "tol_flag=1" "tol=6.000000" "ce_systems=0" "ce_connectivity=0" "ce_nonnormal=0" 
*CE_ConnectorCreateByMarkAndRealizeWithDetails Nodes 1 "spot" 2 Comps 2 "nastran" 5 0 6.0 1 8