Use the OBJ Reference panel to define a response and its reference values for a minmax (maxmin) optimization problem.
Panel Options
Option | Action |
---|---|
dobjref= | Specify a name for the
objective-reference definition. To edit an existing reference, click the button to select an existing objective reference. |
neg reference = | Specify the desired negative reference value. |
pos reference = | Specify the desired positive reference value. |
response = | Click this button to select a response. |
all / loadsteps | Choose between using all
loadsteps or selecting only specific loadsteps. If you choose loadsteps, use the selector to select loadsteps to be part of the objective reference. |
Command Buttons
Button | Action |
---|---|
create | Create the new dobjref entity. |
update | Update the selected dobjref entity. |
review | Once at least one dobjref entity exists, specify it in the dobjref = field and then click review. |
return | Exit the panel. |