MESHF
Bulk Data Entry Defines options for user-defined input of frequency ranges used to define bands in adaptive meshing for acoustic Adaptive Perfectly Matched Layer (APML) analysis.
Format
| (1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) | (9) | (10) |
|---|---|---|---|---|---|---|---|---|---|
| MESHF | MFID | FVAL | F | FRNG | F1 | F2 | |||
| FRNG | F1 | F2 | FVAL | F | |||||
| etc. |
Example
| (1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) | (9) | (10) |
|---|---|---|---|---|---|---|---|---|---|
| MESHF | 7 | FVAL | 10.0 | FRNG | 20.0 | 40.0 | |||
| FVAL | 41.0 | FVAL | 50.0 | ||||||
| FRNG | 51.0 | 80.0 |
Definitions
| Field | Contents | SI Unit Example |
|---|---|---|
| MFID | Mesh frequency identification number. This can be referenced
on the MFID field of PACPML Bulk Data. No default (Integer > 0) |
|
| FVAL | Flag indicating that a single frequency value (F) is to follow. | |
| F | Single frequency value to be a part of the frequency bands.
No default (Real) |
|
| FRNG | Flag indicating that two frequency values (F1, F2) are to follow. | |
| F1, F2 | Two frequency values identifying a frequency range that
defines a frequency band. No default (Real) |
Comments
- Any number of FVALs and FRNGs can be defined on this entry.